Your browser doesn't support javascript.
loading
Evaluation of levobupivacaine passage to breast milk following epidural anesthesia for cesarean delivery.
Bolat, E; Bestas, A; Bayar, M K; Ozcan, S; Erhan, O L; Ustundag, B.
Afiliação
  • Bolat E; Department of Anesthesiology and Reanimation, Bozok University School of Medicine, Yozgat, Turkey.
  • Bestas A; Department of Anesthesiology and Reanimation, Firat University School of Medicine, Elazig, Turkey. Electronic address: abestas@firat.edu.tr.
  • Bayar MK; Department of Anesthesiology and Reanimation, Firat University School of Medicine, Elazig, Turkey.
  • Ozcan S; Department of Anesthesiology and Reanimation, Firat University School of Medicine, Elazig, Turkey.
  • Erhan OL; Department of Anesthesiology and Reanimation, Firat University School of Medicine, Elazig, Turkey.
  • Ustundag B; Department of Biochemistry, Firat University School of Medicine, Elazig, Turkey.
Int J Obstet Anesth ; 23(3): 217-21, 2014 Aug.
Article em En | MEDLINE | ID: mdl-24953218
ABSTRACT

BACKGROUND:

Following maternal administration, local anesthetics pass into breast milk. In the present study, we aimed to compare the passage of levobupivacaine and bupivacaine into breast milk following epidural anesthesia for cesarean delivery.

METHODS:

A total of 20 women undergoing elective cesarean delivery under epidural anesthesia were randomized to receive either 0.5% levobupivacaine or 0.5% racemic bupivacaine via an epidural catheter. Immediately before and 30min, 1h, 2h, 6h, 12h and 24h after administration of epidural local anesthetic, maternal blood and breast milk samples were taken simultaneously. Drug concentrations in plasma and milk were determined via high-performance liquid chromatography. The infant's drug exposure was determined by calculating milk/plasma ratios of levobupivacaine and bupivacaine.

RESULTS:

Both levobupivacaine and bupivacaine were detected in breast milk 30min after epidural administration. Concentrations of both agents showed constant and similar decreases in milk and plasma and were nearly undetectable at 24h. The milk/plasma ratios were 0.34±0.13 for levobupivacaine and 0.37±0.14 for bupivacaine.

CONCLUSIONS:

Both levobupivacaine and bupivacaine pass into breast milk following epidural administration. The concentration of both drugs was approximately three times lower in breast milk than in maternal plasma.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bupivacaína / Cesárea / Anestesia Epidural / Anestesia Obstétrica / Anestésicos Locais / Leite Humano Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Adult / Female / Humans / Newborn / Pregnancy Idioma: En Revista: Int J Obstet Anesth Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bupivacaína / Cesárea / Anestesia Epidural / Anestesia Obstétrica / Anestésicos Locais / Leite Humano Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Adult / Female / Humans / Newborn / Pregnancy Idioma: En Revista: Int J Obstet Anesth Ano de publicação: 2014 Tipo de documento: Article