Your browser doesn't support javascript.
loading
The randomized crossover comparison of airway sealing with the laryngeal mask airway Supreme(™) at three different intracuff pressures in children.
Choi, Kwan-Woong; Lee, Jeong-Rim; Oh, Jung-Tak; Kim, Dong Wook; Kim, Min-Soo.
Afiliação
  • Choi KW; Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Paediatr Anaesth ; 24(10): 1080-7, 2014 Oct.
Article em En | MEDLINE | ID: mdl-25059727
BACKGROUND: An intracuff pressure of 80 cm H2 O in the adult-sized laryngeal mask airway Supreme has been recommended to obtain a higher oropharyngeal leak pressure (OLP). However, the intracuff pressure for the higher OLP in the pediatric laryngeal mask airway Supreme could be different from that in the adult-sized laryngeal mask airway Supreme. Thus, we measured and compared OLP at three intracuff pressures of 40, 60, and 80 cm H2 O in the pediatric laryngeal mask airway Supreme. METHODS: This study was designed as a randomized crossover study and enrolled 36 children, aged 0-108 months and 5-30 kg in weight. After insertion of the laryngeal mask airway Supreme, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 40, 60, and 80 cm H2 O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, the laryngeal mask airway Supreme was maintained using the last intracuff pressure of the allocated sequence. The intraoperative and postoperative complications were compared among three maintenance intracuff pressures. RESULTS: OLP at the intracuff pressure of 60 cm H2 O was significantly higher than that of 40 cm H2 O (17.9 ± 3.9 vs 16.9 ± 4.2 cm H2 O, P = 0.004) and was comparable with that of 80 cm H2 O (17.9 ± 3.9 vs 17.8 ± 4.6 cm H2 O, P = 0.938). There were no significant differences of intraoperative and postoperative complications among the three maintenance intracuff pressures. CONCLUSION: Our results suggest that the use of an intracuff pressure of 60 cm H2 O in pediatric laryngeal mask airway Supreme provides a higher OLP compared with 40 cm H2 O.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas Tipo de estudo: Clinical_trials / Etiology_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: Paediatr Anaesth Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas Tipo de estudo: Clinical_trials / Etiology_studies Limite: Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Revista: Paediatr Anaesth Ano de publicação: 2014 Tipo de documento: Article