Energy drink-induced near-fatal ventricular arrhythmia prevented by an intracardiac defibrillator decades after operative "repair" of tetralogy of Fallot.
Am J Cardiol
; 114(7): 1124-5, 2014 Oct 01.
Article
em En
| MEDLINE
| ID: mdl-25212551
We describe a 45-year old man who experienced a potentially fatal arrhythmia after consumption of multiple energy drinks. At 5 years old, he underwent "repair" of tetralogy of Fallot using a patch in the right ventricular outflow tract, and at age 40 had an automatic implantable cardiac defibrillator (AICD) placed. His first AICD shock occurred within 30 minutes after he finished the third energy drink and was preceded by feelings of lightheadedness and severe dizziness. Without the AICD, he likely would have died. The risk of consuming energy drinks in those with underlying structural heart disease and the general population should be determined. Warning labels should be required to inform consumers of the risks posed by these drinks and of appropriate limits for consumption.
Texto completo:
1
Coleções:
01-internacional
Contexto em Saúde:
1_ASSA2030
/
2_ODS3
Base de dados:
MEDLINE
Assunto principal:
Tetralogia de Fallot
/
Cardioversão Elétrica
/
Taquicardia Ventricular
/
Desfibriladores Implantáveis
/
Bebidas Energéticas
/
Procedimentos Cirúrgicos Cardíacos
Tipo de estudo:
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Am J Cardiol
Ano de publicação:
2014
Tipo de documento:
Article