Your browser doesn't support javascript.
loading
Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.
Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep.
Afiliação
  • Atay A; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Demir L; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Cuhadar S; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Saglam G; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Unal H; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Aksun S; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Arslan B; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Ozkan A; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
  • Sutcu R; Katip Celebi University, Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Izmir, Turkey.
Biochem Med (Zagreb) ; 24(3): 376-82, 2014.
Article em En | MEDLINE | ID: mdl-25351356
ABSTRACT

INTRODUCTION:

Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. MATERIALS AND

METHODS:

This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors.

RESULTS:

A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients.

CONCLUSIONS:

The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Coleta de Amostras Sanguíneas / Técnicas de Laboratório Clínico / Erros de Diagnóstico Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biochem Med (Zagreb) Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Coleta de Amostras Sanguíneas / Técnicas de Laboratório Clínico / Erros de Diagnóstico Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biochem Med (Zagreb) Ano de publicação: 2014 Tipo de documento: Article