Your browser doesn't support javascript.
loading
Targeted Screening and Quantification of dl-PCBs and Dioxins in Various Foodstuffs by Programmed-temperature Vaporizer Large-volume Injection Coupled to GC-MS.
Ho, Ngoc Huy; Bugey, Aurélie; Zimmerli, Pierre; Nançoz, Joëlle; Ortelli, Didier; Edder, Patrick.
Afiliação
  • Ho NH; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland. ngoc-huy.ho@etat.ge.ch.
  • Bugey A; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland.
  • Zimmerli P; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland.
  • Nançoz J; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland.
  • Ortelli D; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland.
  • Edder P; Official Food and Veterinary Control Authority of Geneva, Quai Ernest-Ansermet 22, CH-1205 Geneva, Switzerland.
Chimia (Aarau) ; 68(10): 732-8, 2014 Oct.
Article em En | MEDLINE | ID: mdl-25437167
ABSTRACT
In 2009, high concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) were found in soils located near the municipal garbage incinerator of Geneva. The matter of food contamination in this area was raised. Based on exposure criteria, a strategy of analysis of animal fats has been established with farmers in the Geneva area. Most methods of analysis of dl-PCBs, dioxins and furans, are based on gas chromatography coupled to high-resolution mass spectrometry (GC-HRMS) and considered as the reference methodology. An innovative approach was developed by programmed-temperature vaporizer large-volume injection (PTV-LV) and gas chromatography coupled with triple quadrupole mass spectrometry (GC-MS/MS) analysis. This analytical method was validated and was found suitable for screening and quantification of target compounds in animal fats (beef, pork, sheep, etc. ). PTV-LV coupled to GC-MS/MS appeared to be a good alternative compared to the GC-HRMS strategy, offering a good compromise between sensitivity, versatility of instrumentation, and economical aspects. A survey of 121 samples was conducted.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Dioxinas / Cromatografia Gasosa-Espectrometria de Massas / Carne Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals Idioma: En Revista: Chimia (Aarau) Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Alimentos / Dioxinas / Cromatografia Gasosa-Espectrometria de Massas / Carne Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Animals Idioma: En Revista: Chimia (Aarau) Ano de publicação: 2014 Tipo de documento: Article