Measurement of a multi-layered tear film phantom using optical coherence tomography and statistical decision theory.
Huang, Jinxin; Yuan, Qun; Zhang, Buyun; Xu, Ke; Tankam, Patrice; Clarkson, Eric; Kupinski, Matthew A; Hindman, Holly B; Aquavella, James V; Suleski, Thomas J; Rolland, Jannick P.
Afiliação
  • Huang J; Department of Physics and Astronomy, University of Rochester, Rochester, New York 14627, USA.
  • Yuan Q; The Institute of Optics, University of Rochester, Rochester, New York 14627, USA ; School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu 210094, China.
  • Zhang B; The Institute of Optics, University of Rochester, Rochester, New York 14627, USA ; Department of Optical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
  • Xu K; The Institute of Optics, University of Rochester, Rochester, New York 14627, USA.
  • Tankam P; The Institute of Optics, University of Rochester, Rochester, New York 14627, USA.
  • Clarkson E; Department of Radiology, University of Arizona, Tucson, Arizona 85720, USA.
  • Kupinski MA; College of Optical Sciences, University of Arizona, Tucson, Arizona 85720, USA.
  • Hindman HB; Flaum Eye Institute, University of Rochester, New York 14642, USA.
  • Aquavella JV; Flaum Eye Institute, University of Rochester, New York 14642, USA.
  • Suleski TJ; Department of Physics and Optical Science, The University of North Carolina at Charlotte, Charlotte, North Carolina 28223, USA.
  • Rolland JP; The Institute of Optics, University of Rochester, Rochester, New York 14627, USA.
Biomed Opt Express ; 5(12): 4374-86, 2014 Dec 01.
Article em En | MEDLINE | ID: mdl-25574445
To extend our understanding of tear film dynamics for the management of dry eye disease, we propose a method to optically sense the tear film and estimate simultaneously the thicknesses of the lipid and aqueous layers. The proposed method, SDT-OCT, combines ultra-high axial resolution optical coherence tomography (OCT) and a robust estimator based on statistical decision theory (SDT) to achieve thickness measurements at the nanometer scale. Unlike conventional Fourier-domain OCT where peak detection of layers occurs in Fourier space, in SDT-OCT thickness is estimated using statistical decision theory directly on the raw spectra acquired with the OCT system. In this paper, we demonstrate in simulation that a customized OCT system tailored to ~1 µm axial point spread function (FWHM) in the corneal tissue, combined with the maximum-likelihood estimator, can estimate thicknesses of the nanometer-scale lipid and micron-scale aqueous layers of the tear film, simultaneously, with nanometer precision. This capability was validated in experiments using a physical phantom that consists of two layers of optical coatings that mimic the lipid and aqueous layers of the tear film.