Your browser doesn't support javascript.
loading
[A decade of lead monitoring in schoolchildren in the metropolitan area of Monterrey NL, Mexico]. / Una década de monitoreo de plomo en sangre en niños escolares del área metropolitana de Monterrey, NL.
Santos-Guzmán, Jesús; Madrigal-Ávila, Claudia; Hernández-Hernández, José Ascención; Mejía-Velázquez, Gerardo; Eraña-Rojas, Irma Elisa; Elizondo-Montemayor, Leticia; Villela, Luis.
Afiliação
  • Santos-Guzmán J; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Madrigal-Ávila C; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Hernández-Hernández JA; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Mejía-Velázquez G; Centro de Calidad Ambiental, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Eraña-Rojas IE; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Elizondo-Montemayor L; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
  • Villela L; Escuela de Medicina del Tecnológico de Monterrey, Instituto Tecnológico y de Estudios Superiores de Monterrey, Monterrey, Nuevo León, México.
Salud Publica Mex ; 56(6): 592-602, 2014.
Article em Es | MEDLINE | ID: mdl-25604410
ABSTRACT

OBJECTIVE:

To establish the blood lead concentration and associated risk factors in schoolchildren during 1998 and 2008. MATERIALS AND

METHODS:

A blood lead screening was conducted in schoolchildren of 6-12 years of age, enrolled in 17 elementary schools of the metropolitan area of Monterrey, México, during 1998 and 2008.

RESULTS:

The mean blood lead level were 9.6 ± 3.0 (µg/dL range of 3.18 to 20.88) in 1998 and 4.5±4.8 µg/dL (range of 3.3 to 53.7) showing a 2.1-times reduction in blood lead levels (p<0.01).

CONCLUSIONS:

This reduction in blood lead levels demonstrate environmental and industrial control improvements and the benefits of fading out the leaded gasoline during the 1990's.
Assuntos

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Chumbo Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Child / Female / Humans / Male País/Região como assunto: Mexico Idioma: Es Revista: Salud Publica Mex Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Chumbo Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Child / Female / Humans / Male País/Região como assunto: Mexico Idioma: Es Revista: Salud Publica Mex Ano de publicação: 2014 Tipo de documento: Article