Your browser doesn't support javascript.
loading
Analytical potential of a laser ablation-glow discharge-optical emission spectrometry system for the analysis of conducting and insulating materials.
González de Vega, Claudia; Álvarez Llamas, Cesar; Bordel, Nerea; Pereiro, Rosario; Sanz-Medel, Alfredo.
Afiliação
  • González de Vega C; University of Oviedo, Department of Physical and Analytical Chemistry, Julián Clavería 8, 33006 Oviedo, Spain.
  • Álvarez Llamas C; University of Oviedo, Department of Physics, Calvo Sotelo s/n, 33007 Oviedo, Spain.
  • Bordel N; University of Oviedo, Department of Physics, Calvo Sotelo s/n, 33007 Oviedo, Spain. Electronic address: bordel@uniovi.es.
  • Pereiro R; University of Oviedo, Department of Physical and Analytical Chemistry, Julián Clavería 8, 33006 Oviedo, Spain. Electronic address: mrpereiro@uniovi.es.
  • Sanz-Medel A; University of Oviedo, Department of Physical and Analytical Chemistry, Julián Clavería 8, 33006 Oviedo, Spain.
Anal Chim Acta ; 877: 33-40, 2015 Jun 02.
Article em En | MEDLINE | ID: mdl-26002208
ABSTRACT
The analytical capabilities of a glow discharge (GD) as a secondary source for excitation/ionization of the material provided by laser ablation (LA) have been compared to conventional laser induced breakdown spectroscopy (LIBS). In LA-GD both sources can be independently adjusted to optimize the sampling process and then its subsequent excitation. This could involve a number of analytical performance advantages, such as reduced matrix dependence, greater precision and sensitivity than those encountered in LIBS. For such purpose, an ablation chamber design including two electrodes to generate the GD discharge has been built and assayed. A comparison between LIBS and LA-GD-OES has been carried out, both, under reduced argon and helium atmospheres. Different sets of samples (conducting reference materials, glass and fluorine pellets) have been used to evaluate the novel coupled technique. The LA-GD coupled system has shown to provide lower detection limits. In addition, best linear correlations between intensities and concentrations and lower matrix effects have also been found using the coupled system. Moreover, special advantages of the LA-GD-OES have also been demonstrated for the analysis of fluorine.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chim Acta Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chim Acta Ano de publicação: 2015 Tipo de documento: Article