Porcine Model to Evaluate Real-Time Intraocular Pressure During Femtosecond Laser Cataract Surgery.
Ibarz, Marta; Hernández-Verdejo, José Luis; Bolívar, Gema; Tañá, Pedro; Rodríguez-Prats, José Luis; Teus, Miguel A.
Afiliação
  • Ibarz M; a Hospital Moncloa, Oftalvist Madrid , Madrid , Spain .
  • Hernández-Verdejo JL; b VISSUM Madrid , Madrid , Spain .
  • Bolívar G; c Hospital Príncipe de Asturias , Alcalá de Henares, Madrid , Spain .
  • Tañá P; d Clínica Vistahermosa, Oftalvist Alicante , Alicante , Spain , and.
  • Rodríguez-Prats JL; d Clínica Vistahermosa, Oftalvist Alicante , Alicante , Spain , and.
  • Teus MA; e Hospital Príncipe de Asturias, Universidad de Alcalá de Henares , Madrid , Spain.
Curr Eye Res ; 41(4): 507-12, 2016 04.
Article em En | MEDLINE | ID: mdl-26016665
PURPOSE: To investigate the changes in intraocular pressure (IOP) in porcine eyes during femtosecond laser-assisted cataract surgery using a liquid-optic interface system. MATERIALS AND METHODS: Femtosecond laser cataract surgery with the Catalys™ was performed on freshly enucleated porcine eyes in Oftalvist Moncloa, Madrid, Spain. Capsulorhexis and lens fragmentation were completed in all the eyes without complications. IOP was measured with a reusable blood pressure transducer connected by direct cannulation to the anterior chamber, recording data before suction (basal), at the beginning of the suction phase, every five seconds during femtosecond procedure and after the removal of the suction ring from the eye. RESULTS: Nine porcine eyes were used in this study. Basal IOP before suction was 5.67 ± 2.39 mmHg, rising to 20.33 ± 4.18 mmHg at the beginning of the suction phase (p < 0.001). During femtosecond procedure, pressure reached a value of 19.74 ± 4.31 mmHg, remaining stable during the entire process. The IOP recorded prior to removal of the suction ring was 21.00 ± 6.93 mmHg, returning to basal values in all the eyes after the suction ring was removed, with no statistical differences between basal and post-suction IOPs. Total femtosecond procedure time was 125.9 ± 15.9 s. CONCLUSIONS: Real-time IOP can be measured during surgery using a transducer connected to the anterior chamber. The results showed a significant increase in IOP during the procedure due to the pressure exerted by the suction ring but not by the effect of the femtosecond laser.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Extração de Catarata / Monitorização Intraoperatória / Terapia a Laser / Pressão Intraocular Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Curr Eye Res Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Extração de Catarata / Monitorização Intraoperatória / Terapia a Laser / Pressão Intraocular Tipo de estudo: Observational_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Curr Eye Res Ano de publicação: 2016 Tipo de documento: Article