Tibial Stems in Revision Total Knee Arthroplasty: Is There an Anatomic Conflict?
Gobba, Mohamed S; Chan, Newton; Patel, Rikin; Noble, Philip C; Incavo, Stephen J.
Afiliação
  • Gobba MS; Houston Methodist Hospital, Houston, Texas.
  • Chan N; Institute for Orthopedic Research and Education, Houston, Texas.
  • Patel R; Houston Methodist Hospital, Houston, Texas.
  • Noble PC; Institute for Orthopedic Research and Education, Houston, Texas.
  • Incavo SJ; Houston Methodist Hospital, Houston, Texas.
J Arthroplasty ; 30(9 Suppl): 86-9, 2015 Sep.
Article em En | MEDLINE | ID: mdl-26118566
ABSTRACT
Tibial stems are frequently used in revision total knee arthroplasty (TKA). We investigated the effect of tibial stems on final component alignment and tray position. Thirty 3D reconstructed cadaveric tibial models were classified according to canal bow angle. After virtual implantation of 120 mm and 200 mm stemmed tibial components, deviation from native mechanical axis was measured. Tibial alignment valgus malposition of up to three degrees occurred and most pronounced with 120 mm stems. Canal alignment using 200 mm stems deviated tray position medially and posteriorly. Mild to moderate valgus bowing of the tibial canal is not uncommon (57% in our series) possibly leading to valgus malalignment. Anatomic conflict between the tibial mechanical axis and intramedullary canal can exist, with alignment and tray placement implications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Tíbia / Artroplastia do Joelho Limite: Humans Idioma: En Revista: J Arthroplasty Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Tíbia / Artroplastia do Joelho Limite: Humans Idioma: En Revista: J Arthroplasty Ano de publicação: 2015 Tipo de documento: Article