Your browser doesn't support javascript.
loading
Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.
Miller, Brian W; Frost, Sofia H L; Frayo, Shani L; Kenoyer, Aimee L; Santos, Erlinda; Jones, Jon C; Green, Damian J; Hamlin, Donald K; Wilbur, D Scott; Fisher, Darrell R; Orozco, Johnnie J; Press, Oliver W; Pagel, John M; Sandmaier, Brenda M.
Afiliação
  • Miller BW; Pacific Northwest National Laboratory, Richland, Washington 99354 and College of Optical Sciences, The University of Arizona, Tucson, Arizona 85719.
  • Frost SH; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Frayo SL; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Kenoyer AL; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Santos E; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Jones JC; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Green DJ; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 and Department of Medicine, University of Washington, Seattle, Washington 98195.
  • Hamlin DK; Department of Radiation Oncology, University of Washington, Seattle, Washington 98195.
  • Wilbur DS; Department of Radiation Oncology, University of Washington, Seattle, Washington 98195.
  • Fisher DR; Dade Moeller Health Group, Richland, Washington 99354.
  • Orozco JJ; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109.
  • Press OW; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 and Department of Medicine, University of Washington, Seattle, Washington 98195.
  • Pagel JM; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 and Department of Medicine, University of Washington, Seattle, Washington 98195.
  • Sandmaier BM; Fred Hutchinson Cancer Research Center, Seattle, Washington 98109 and Department of Medicine, University of Washington, Seattle, Washington 98195.
Med Phys ; 42(7): 4094-105, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26133610
ABSTRACT

PURPOSE:

Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 µm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments.

METHODS:

The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ((211)At) activity distributions in cryosections of murine and canine tissue samples.

RESULTS:

The highest spatial resolution was measured at ∼20 µm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10(-4) cpm/cm(2) (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the (211)At activity distribution was demonstrated at mBq/µg-levels.

CONCLUSIONS:

Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Autorradiografia / Câmaras gama / Radioimunoterapia Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Med Phys Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Autorradiografia / Câmaras gama / Radioimunoterapia Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: Med Phys Ano de publicação: 2015 Tipo de documento: Article