Your browser doesn't support javascript.
loading
Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.
Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh.
Afiliação
  • Ye BW; From the Division of Gastroenterology (B-WY, K-CL, Y-CH, C-PL, YC, M-CH, H-CL), Department of Medicine; Cancer Center (YC); Endoscopic Diagnosis and Therapeutic Center (M-CH), Taipei Veterans General Hospital; and Department of Medicine (B-WY, K-CL, Y-CH, C-PL, YC, M-CH, H-CL), National Yang-Ming University School of Medicine, Taipei, Taiwan.
Medicine (Baltimore) ; 94(29): e1208, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26200641
ABSTRACT
Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR] 0.28, P = 0.01). Cancer with gastric origin (HR 0.25, P = 0.045) and poststent chemotherapy (HR 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Promover_ampliacao_atencao_especializada Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Stents / Obstrução da Saída Gástrica / Neoplasias Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Promover_ampliacao_atencao_especializada Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Stents / Obstrução da Saída Gástrica / Neoplasias Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2015 Tipo de documento: Article