Full-Arch, Implant-Supported Monolithic Zirconia Rehabilitations: Pilot Clinical Evaluation of Wear Against Natural or Composite Teeth.
Cardelli, Paolo; Manobianco, Francesco Pio; Serafini, Nicola; Murmura, Giovanna; Beuer, Florian.
Afiliação
  • Cardelli P; Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.
  • Manobianco FP; Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.
  • Serafini N; Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.
  • Murmura G; Department of Medical, Oral and Biotechnological Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.
  • Beuer F; Department of Prosthodontics, Geriatic Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Berlin, Germany.
J Prosthodont ; 25(8): 629-633, 2016 Dec.
Article em En | MEDLINE | ID: mdl-26436677
ABSTRACT

PURPOSE:

To clinically evaluate the amount of contact wear generated between full-arch monolithic zirconia implant-supported restorations and natural or composite antagonists, over a 1-year period. MATERIALS AND

METHODS:

Forty-seven teeth from clinically functional, full-arch monolithic zirconia screw-retained implant prostheses (FDPs) and their antagonists were investigated. The first group ("Zirconia-E") was opposed to natural teeth ("Enamel"), whereas the other one ("Zirconia-CR") was opposed to nano-hybrid composite teeth ("Composite Resin"). Replicas of the restorations and their antagonists were obtained immediately after delivery (T0 ) and after 1 year of clinical service (T1 ). Each tooth surface was individually evaluated three-dimensionally by software to quantify the vertical distance between the two scans (Hausdorff distance), which was considered as contact wear. Data obtained for each arch were subjected to one-way ANOVA test and a post hoc analysis (Tukey's test) at a 5% level of significance. Furthermore, the influence of the location of the teeth (anterior or posterior) was analyzed. Minimum post hoc statistical power between statistically different groups was 99.6%.

RESULTS:

Mean values were 63 ± 23 µm for Zirconia-E, 76 ± 29 µm for enamel, 70 ± 38 µm for composite resin; Zirconia-CR had a mean value of 19 ± 4 µm and significantly differed from the other groups. Contact wear between anterior and posterior teeth differed significantly only in the composite resin arch, with a mean of 39 ± 22 µm for anterior teeth versus 101 ± 19 µm for posterior ones.

CONCLUSIONS:

Within the limitations of this preliminary evaluation, monolithic zirconia full-arch rehabilitations induced a clinically acceptable wear on natural and composite antagonists over a 1-year period; they might be considered a viable solution for implant-supported rehabilitations.