Your browser doesn't support javascript.
loading
The positive frequency-dependent electrophysiological effects of the IKur inhibitor XEN-D0103 are desirable for the treatment of atrial fibrillation.
Ford, John; Milnes, James; El Haou, Said; Wettwer, Erich; Loose, Simone; Matschke, Klaus; Tyl, Benoit; Round, Patrick; Ravens, Ursula.
Afiliação
  • Ford J; Xention Ltd, Cambridge, United Kingdom.
  • Milnes J; Xention Ltd, Cambridge, United Kingdom.
  • El Haou S; Xention Ltd, Cambridge, United Kingdom.
  • Wettwer E; Department of Pharmacology and Toxicology, Medical Faculty Carl Gustav Carus, Dresden, Germany.
  • Loose S; Department of Pharmacology and Toxicology, Medical Faculty Carl Gustav Carus, Dresden, Germany.
  • Matschke K; Clinic for Cardiac Surgery, Heart Center Dresden, Dresden, Germany.
  • Tyl B; Institut de Recherches Internationales Servier, Suresnes, France.
  • Round P; Xention Ltd, Cambridge, United Kingdom.
  • Ravens U; Department of Pharmacology and Toxicology, Medical Faculty Carl Gustav Carus, Dresden, Germany. Electronic address: ravens@rcs.urz.tu-dresden.de.
Heart Rhythm ; 13(2): 555-64, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26455450
ABSTRACT

BACKGROUND:

Selective inhibitors of Kv1.5 channels are being developed for the treatment of atrial fibrillation (AF).

OBJECTIVES:

The purpose of this study was to investigate the effects of the highly selective Kv1.5 inhibitor XEN-D0103 on human atrial action potentials (APs) at high excitation rates and to assess safety.

METHODS:

Intracellular APs (stimulation rates 1-5 Hz) were measured in right atrial trabeculae from patients in sinus rhythm (SR), chronic AF (cAF; AF of >6 months duration), and paroxysmal AF (pAF). The safety and tolerability of XEN-D0103 were tested in a double-blind, randomized, placebo-controlled phase 1 study.

RESULTS:

Depending on its concentration, XEN-D0103 elevated the plateau potential. At 1 Hz, XEN-D0103 (3 µM) shortened action potential duration at 90% repolarization (APD90) and effective refractory period (ERP) in SR preparations, but prolonged these parameters in cAF preparations. In SR and pAF preparations, the shortening effects on APD90 and ERP turned into prolongation at high rates. In cAF trabeculae, XEN-D0103 prolonged APD90 and ERP at 2 and 3 Hz. At high rates, more SR and pAF preparations failed to capture excitation in the presence of the drug than in its absence. XEN-D0103 (10 µM) did not significantly affect human ventricular APs. Even with plasma concentrations reaching 7000 ng/mL, XEN-D0103 did not increase ∆∆QTcF (QT interval corrected by the Fridericia formula) in the analysis of electrocardiograms of healthy volunteers, and no subjects receiving an active treatment had a QT or QTcF interval >450 ms, or increase in QTcF from baseline >30 ms.

CONCLUSION:

APD prolongation and suppression of APs by XEN-D0103 at high stimulation rates in SR and pAF tissue, but not cAF, could be of therapeutic benefit for reducing AF burden. This concept needs to be confirmed in clinical trials.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Período Refratário Eletrofisiológico / Fibrilação Atrial / Potenciais de Ação / Canais de Potássio de Retificação Tardia / Antiarrítmicos Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Período Refratário Eletrofisiológico / Fibrilação Atrial / Potenciais de Ação / Canais de Potássio de Retificação Tardia / Antiarrítmicos Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Humans / Male Idioma: En Revista: Heart Rhythm Ano de publicação: 2016 Tipo de documento: Article