Your browser doesn't support javascript.
loading
Efficiency of an automated reception and turnaround time management system for the phlebotomy room.
Yun, Soon Gyu; Shin, Jeong Won; Park, Eun Su; Bang, Hae In; Kang, Jung Gu.
Afiliação
  • Yun SG; Department of Laboratory Medicine, Soonchunhyang University Hospital, Seoul, Korea.
  • Shin JW; Department of Laboratory Medicine, Kangwon National University School of Medicine, Chuncheon, Korea.
  • Park ES; Department of Laboratory Medicine, Soonchunhyang University Hospital, Seoul, Korea. jwshin@schmc.ac.kr.
  • Bang HI; Department of Laboratory Medicine, Soonchunhyang University Hospital, Seoul, Korea.
  • Kang JG; Department of Laboratory Medicine, Soonchunhyang University Hospital, Seoul, Korea.
Ann Lab Med ; 36(1): 49-54, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26522759
ABSTRACT

BACKGROUND:

Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient's information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance.

METHODS:

The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system.

RESULTS:

Mean TAT decreased from 545 min to 242 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%.

CONCLUSIONS:

The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eficiência Organizacional / Flebotomia Tipo de estudo: Prognostic_studies País/Região como assunto: Asia Idioma: En Revista: Ann Lab Med Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eficiência Organizacional / Flebotomia Tipo de estudo: Prognostic_studies País/Região como assunto: Asia Idioma: En Revista: Ann Lab Med Ano de publicação: 2016 Tipo de documento: Article