Perchlorate formation during the electro-peroxone treatment of chloride-containing water: Effects of operational parameters and control strategies.
Lin, Zhirong; Yao, Weikun; Wang, Yujue; Yu, Gang; Deng, Shubo; Huang, Jun; Wang, Bin.
Afiliação
  • Lin Z; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
  • Yao W; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
  • Wang Y; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China. Electronic address: wangyujue@tsinghua.edu.cn.
  • Yu G; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
  • Deng S; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
  • Huang J; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
  • Wang B; School of Environment, Beijing Key Laboratory for Emerging Organic Contaminants Control, State Key Joint Laboratory of Environmental Simulation and Pollution Control, Tsinghua University, Beijing 100084, China.
Water Res ; 88: 691-702, 2016 Jan 01.
Article em En | MEDLINE | ID: mdl-26580085
This study investigated the degradation of clofibric acid and formation of perchlorate during the electro-peroxone (E-peroxone) treatment of chloride-containing (26.1-100 mg L(-1)) water (Na2SO4 electrolytes and secondary effluents). The E-peroxone process involves sparging O2 and O3 gas mixture into an electrolysis reactor where a carbon-based cathode is used to electrochemically convert the sparged O2 to H2O2. The electro-generated H2O2 then reacts with sparged O3 to produce OH, which can rapidly oxidize pollutants in the bulk solution. When boron-doped diamond (BDD) electrodes were used as the anode, perchlorate concentrations increased significantly from undetectable levels to ∼15-174 mg L(-1) in the different water samples as the applied current density was increased from 4 to 32 mA cm(-2). In contrast, no ClO4(-) was detected when Pt/Ti anodes were used in the E-peroxone process operated under similar reaction conditions. In addition, when sufficient O3 was sparged to maximize OH production from its peroxone reaction with electro-generated H2O2, the E-peroxone process with Pt/Ti anodes achieved comparable clofibric acid degradation and total organic carbon (TOC) removal yields as that with BDD anodes, but did not generate detectable ClO4(-). These results indicate that by optimizing operational parameters and using Pt/Ti anodes, the E-peroxone process can achieve the goal of both fast pollutant degradation and ClO4(-) prevention during the treatment of chloride-containing wastewater.