Your browser doesn't support javascript.
loading
Automatic labeling of cerebral arteries in magnetic resonance angiography.
Dunås, Tora; Wåhlin, Anders; Ambarki, Khalid; Zarrinkoob, Laleh; Birgander, Richard; Malm, Jan; Eklund, Anders.
Afiliação
  • Dunås T; Department of Radiation Sciences, Umeå University, S-901 87, Umeå, Sweden. tora.dunas@umu.se.
  • Wåhlin A; Department of Radiation Sciences, Umeå University, S-901 87, Umeå, Sweden.
  • Ambarki K; Umeå Center for Functional Brain Imaging, Umeå University, S-901 87, Umeå, Sweden.
  • Zarrinkoob L; Department of Radiation Sciences, Umeå University, S-901 87, Umeå, Sweden.
  • Birgander R; Centre for Biomedical Engineering and Physics, Umeå University, S-901 87, Umeå, Sweden.
  • Malm J; Department of Clinical Neuroscience, Umeå University, S-901 87, Umeå, Sweden.
  • Eklund A; Department of Radiation Sciences, Umeå University, S-901 87, Umeå, Sweden.
MAGMA ; 29(1): 39-47, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26646523
ABSTRACT

OBJECTIVES:

In order to introduce 4D flow magnetic resonance imaging (MRI) as a standard clinical instrument for studying the cerebrovascular system, new and faster postprocessing tools are necessary. The objective of this study was to construct and evaluate a method for automatic identification of individual cerebral arteries in a 4D flow MRI angiogram. MATERIALS AND

METHODS:

Forty-six elderly individuals were investigated with 4D flow MRI. Fourteen main cerebral arteries were manually labeled and used to create a probabilistic atlas. An automatic atlas-based artery identification method (AAIM) was developed based on vascular-branch extraction and the atlas was used for identification. The method was evaluated by comparing automatic with manual identification in 4D flow MRI angiograms from 67 additional elderly individuals.

RESULTS:

Overall accuracy was 93%, and internal carotid artery and middle cerebral artery labeling was 100% accurate. Smaller and more distal arteries had lower accuracy; for posterior communicating arteries and vertebral arteries, accuracy was 70 and 89%, respectively.

CONCLUSION:

The AAIM enabled fast and fully automatic labeling of the main cerebral arteries. AAIM functionality provides the basis for creating an automatic and powerful method to analyze arterial cerebral blood flow in clinical routine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias Cerebrais / Angiografia por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: MAGMA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias Cerebrais / Angiografia por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: MAGMA Ano de publicação: 2016 Tipo de documento: Article