Your browser doesn't support javascript.
loading
Retinal Arteriolar Morphometry Based on Full Width at Half Maximum Analysis of Spectral-Domain Optical Coherence Tomography Images.
Tong, Yu Hua; Zhu, Tie Pei; Zhao, Ze Lin; Zhan, Hai Jing; Jiang, Fang Zheng; Lian, Heng Li.
Afiliação
  • Tong YH; Quzhou People's Hospital, Quzhou Central Hospital of Zhejiang Chinese Medical University, Quzhou, Zhejiang Province, China.
  • Zhu TP; Eye Center of Affiliated Second Hospital, Medical College of Zhejiang University, Hangzhou, Zhejiang Province, China.
  • Zhao ZL; Eye Hospital of Wenzhou Medical University, Zhejiang Eye Hospital, Wenzhou, Zhejiang Province, China.
  • Zhan HJ; Quzhou People's Hospital, Quzhou Central Hospital of Zhejiang Chinese Medical University, Quzhou, Zhejiang Province, China.
  • Jiang FZ; Quzhou People's Hospital, Quzhou Central Hospital of Zhejiang Chinese Medical University, Quzhou, Zhejiang Province, China.
  • Lian HL; Eye Hospital of Wenzhou Medical University, Zhejiang Eye Hospital, Wenzhou, Zhejiang Province, China.
PLoS One ; 10(12): e0144437, 2015.
Article em En | MEDLINE | ID: mdl-26650940
ABSTRACT

OBJECTIVES:

In this study, we develop a microdensitometry method using full width at half maximum (FWHM) analysis of the retinal vascular structure in a spectral-domain optical coherence tomography (SD-OCT) image and present the application of this method in the morphometry of arteriolar changes during hypertension.

METHODS:

Two raters using manual and FWHM methods measured retinal vessel outer and lumen diameters in SD-OCT images. Inter-rater reproducibility was measured using coefficients of variation (CV), intraclass correlation coefficient and a Bland-Altman plot. OCT images from forty-three eyes of 43 hypertensive patients and 40 eyes of 40 controls were analyzed using an FWHM approach; wall thickness, wall cross-sectional area (WCSA) and wall to lumen ratio (WLR) were subsequently calculated.

RESULTS:

Mean difference in inter-rater agreement ranged from -2.713 to 2.658 µm when using a manual method, and ranged from -0.008 to 0.131 µm when using a FWHM approach. The inter-rater CVs were significantly less for the FWHM approach versus the manual method (P < 0.05). Compared with controls, the wall thickness, WCSA and WLR of retinal arterioles were increased in the hypertensive patients, particular in diabetic hypertensive patients.

CONCLUSIONS:

The microdensitometry method using a FWHM algorithm markedly improved inter-rater reproducibility of arteriolar morphometric analysis, and SD-OCT may represent a promising noninvasive method for in vivo arteriolar morphometry.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteríolas / Doenças Retinianas / Interpretação de Imagem Assistida por Computador / Tomografia de Coerência Óptica / Hipertensão Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arteríolas / Doenças Retinianas / Interpretação de Imagem Assistida por Computador / Tomografia de Coerência Óptica / Hipertensão Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: PLoS One Ano de publicação: 2015 Tipo de documento: Article