Your browser doesn't support javascript.
loading
Validation of automatic segmentation of ribs for NTCP modeling.
Stam, Barbara; Peulen, Heike; Rossi, Maddalena M G; Belderbos, José S A; Sonke, Jan-Jakob.
Afiliação
  • Stam B; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • Peulen H; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • Rossi MM; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • Belderbos JS; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
  • Sonke JJ; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands. Electronic address: j.sonke@nki.nl.
Radiother Oncol ; 118(3): 528-34, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26743835
ABSTRACT
BACKGROUND AND

PURPOSE:

Determination of a dose-effect relation for rib fractures in a large patient group has been limited by the time consuming manual delineation of ribs. Automatic segmentation could facilitate such an analysis. We determine the accuracy of automatic rib segmentation in the context of normal tissue complication probability modeling (NTCP). MATERIALS AND

METHODS:

Forty-one patients with stage I/II non-small cell lung cancer treated with SBRT to 54 Gy in 3 fractions were selected. Using the 4DCT derived mid-ventilation planning CT, all ribs were manually contoured and automatically segmented. Accuracy of segmentation was assessed using volumetric, shape and dosimetric measures. Manual and automatic dosimetric parameters Dx and EUD were tested for equivalence using the Two One-Sided T-test (TOST), and assessed for agreement using Bland-Altman analysis. NTCP models based on manual and automatic segmentation were compared.

RESULTS:

Automatic segmentation was comparable with the manual delineation in radial direction, but larger near the costal cartilage and vertebrae. Manual and automatic Dx and EUD were significantly equivalent. The Bland-Altman analysis showed good agreement. The two NTCP models were very similar.

CONCLUSIONS:

Automatic rib segmentation was significantly equivalent to manual delineation and can be used for NTCP modeling in a large patient group.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 2_ODS3 Base de dados: MEDLINE Assunto principal: Costelas / Planejamento da Radioterapia Assistida por Computador / Modelos Estatísticos / Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Radiother Oncol Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 / 2_ODS3 Base de dados: MEDLINE Assunto principal: Costelas / Planejamento da Radioterapia Assistida por Computador / Modelos Estatísticos / Carcinoma Pulmonar de Células não Pequenas / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Radiother Oncol Ano de publicação: 2016 Tipo de documento: Article