Your browser doesn't support javascript.
loading
Sample Confirmation Testing: A Short Tandem Repeat-Based Quality Assurance and Quality Control Procedure for the eyeGENE Biorepository.
Parrish, Rebecca S; Garafalo, Alexandra V; Ndifor, Vida; Goetz, Kerry E; Reeves, Melissa J; Yim, Annette; Cooper, Remy C; Iano-Fletcher, Jemma; Wang, Xinjing; Tumminia, Santa J.
Afiliação
  • Parrish RS; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Garafalo AV; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Ndifor V; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Goetz KE; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Reeves MJ; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Yim A; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Cooper RC; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Iano-Fletcher J; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Wang X; 1 Ophthalmic Genetics and Visual Function Branch, National Eye Institute/NIH , Bethesda, Maryland.
  • Tumminia SJ; 2 Office of the Director, National Eye Institute/NIH , Bethesda, Maryland.
Biopreserv Biobank ; 14(2): 149-55, 2016 Apr.
Article em En | MEDLINE | ID: mdl-26891080
ABSTRACT
Quality assurance and quality control (QA/QC) procedures are vital to good biorepository management. The National Eye Institute (NEI) core CLIA-certified laboratory of the eyeGENE(®) Network receives blood from individuals with inherited eye conditions and isolates DNA for clinical genetic diagnostic testing and research. Clinical genetic test results are returned to the affected individuals, making it imperative that sample integrity is preserved throughout laboratory processing. A clinically validated, short tandem repeat (STR)-based approach, termed Sample Confirmation Testing (SCT), was developed to ensure that no significant laboratory errors occurred during processing. SCT uses modified protocols from commercial kits to create and compare STR profiles for each participant's original blood and derived DNA. This QA/QC procedure has been performed on 47% of the more than 6000 participants in the eyeGENE Biorepository and has identified significant laboratory errors in 0.4% of samples tested. SCT improves the quality of the data returned to affected individuals and the data distributed to researchers using eyeGENE samples by ensuring the integrity of the samples and aiding in curation of the biorepository. This approach serves as a model for other repositories to improve sample quality and management procedures.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Bancos de Espécimes Biológicos / Repetições de Microssatélites / Olho / Oftalmopatias Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Biopreserv Biobank Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Bancos de Espécimes Biológicos / Repetições de Microssatélites / Olho / Oftalmopatias Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Biopreserv Biobank Ano de publicação: 2016 Tipo de documento: Article