Your browser doesn't support javascript.
loading
Fine-tuning to minimize emittances of J-PARC RF-driven H⁻ ion source.
Ueno, A; Ohkoshi, K; Ikegami, K; Takagi, A; Asano, H; Oguri, H.
Afiliação
  • Ueno A; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
  • Ohkoshi K; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
  • Ikegami K; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
  • Takagi A; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
  • Asano H; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
  • Oguri H; J-PARC Center, Tokai-Mura, Naka-Gun, Ibaraki-Ken 319-1195, Japan.
Rev Sci Instrum ; 87(2): 02B130, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26932012
ABSTRACT
The Japan Proton Accelerator Research Complex (J-PARC) cesiated RF-driven H(-) ion source has been successfully operated for about one year. By the world's brightest level beam, the J-PARC design beam power of 1 MW was successfully demonstrated. In order to minimize the transverse emittances, the rod-filter-field (RFF) was optimized by changing the triple-gap-lengths of each of pairing five piece rod-filter-magnets. The larger emittance degradation seems to be caused by impurity-gases than the RFF. The smaller beam-hole-diameter of the extraction electrode caused the more than expected improvements on not only the emittances but also the peak beam intensity.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2016 Tipo de documento: Article