Your browser doesn't support javascript.
loading
Telemedicine for ophthalmic consultation services: use of a portable device and layering information for graders.
Woodward, Maria A; Bavinger, J Clay; Amin, Sejal; Blachley, Taylor S; Musch, David C; Lee, Paul P; Newman-Casey, Paula Anne.
Afiliação
  • Woodward MA; 1 Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, MI, USA.
  • Bavinger JC; 2 Institute for Healthcare Policy & Innovation, University of Michigan, Ann Arbor, MI, USA.
  • Amin S; 1 Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, MI, USA.
  • Blachley TS; 3 Department of Ophthalmology, Henry Ford Health System, Detroit, MI, USA.
  • Musch DC; 1 Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, MI, USA.
  • Lee PP; 1 Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, Ann Arbor, MI, USA.
  • Newman-Casey PA; 4 Department of Epidemiology, University of Michigan School of Public Health, Ann Arbor, MI, USA.
J Telemed Telecare ; 23(2): 365-370, 2017 Feb.
Article em En | MEDLINE | ID: mdl-26936864
ABSTRACT
Introduction We compared remote, image-based patient consultations to in-person consultations at emergency department and inpatient hospital settings. Methods Patients evaluated by the ophthalmic consultation services (gold standard) were imaged over a two-week period. A trained study coordinator took anterior segment photographs (AS) and posterior segment photographs (PS) with a portable camera (PictorPlus, Volk Optical, Cleveland, OH). Ophthalmologists (graders) determined photograph quality, presence of pathology, and their confidence in disease detection. At a separate session, graders reassessed photographs accompanied by a one-sentence summary of demographics and chief complaint (CHx). We computed accuracy and reliability statistics. Results We took AS photographs of 24 eyes of 15 patients and PS photographs of 39 eyes of 20 patients. The majority of images were rated as acceptable or excellent in quality (AS 89-96%; PS 70-75%). Graders detected AS pathology with 62-81% sensitivity based on photographs, increasing to 87-88% sensitivity with photographs plus CHx. Graders detected PS pathology with 79-86% sensitivity based on a photograph only, increasing to 100% sensitivity with photographs plus CHx. Discussion In this pilot study, there is evidence that portable ophthalmic imaging technologies could enable ophthalmologists to remotely evaluate anterior and posterior segment eye diseases with good sensitivity. The ophthalmologist could detect ocular pathology on photographs more accurately if they were provided brief clinical information.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consulta Remota / Oftalmopatias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Telemed Telecare Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consulta Remota / Oftalmopatias Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: J Telemed Telecare Ano de publicação: 2017 Tipo de documento: Article