Your browser doesn't support javascript.
loading
Ratiometric electrochemical immunoassay based on internal reference value for reproducible and sensitive detection of tumor marker.
Cai, Xiaohui; Weng, Shaohuang; Guo, Rubin; Lin, Liqing; Chen, Wei; Zheng, Zongfu; Huang, Zhengjun; Lin, Xinhua.
Afiliação
  • Cai X; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China.
  • Weng S; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China. Electronic address: shweng@fjmu.edu.cn.
  • Guo R; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China.
  • Lin L; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China.
  • Chen W; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China.
  • Zheng Z; 476 Hospital of PLA, Fuzhou 350002, China.
  • Huang Z; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China.
  • Lin X; Department of Pharmaceutical Analysis, Faculty of Pharmacy, the Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Fujian Medical University, Fuzhou 350108, China. Electronic address: xhl1963@sina.com.
Biosens Bioelectron ; 81: 173-180, 2016 Jul 15.
Article em En | MEDLINE | ID: mdl-26945184
A ratiometric assay in an electrochemical immunosensor for tumor marker, herein carcinoembryonic antigen (CEA) was chosen as a model analyte, was developed to improve simplicity and accuracy. The immunosensor was fabricated via the simple expedient way of using Polythionine-gold (PTh-Au) as electrode modified material to be an internal reference signal and K3[Fe(CN)6] in electrolyte as an indicator signal. When the CEA was fixed on the modified electrode via immunoreaction, only the indicator signal sensitively altered; by contrast, the internal reference signal of PTh-Au remained constant at a suitable pH of the electrolyte. The ratio between the alterations of the indicator signal of K3[Fe(CN)6] and the constant internal reference signal can be used to monitor the concentration of CEA reliably, reproducibly, and sensitively. The prepared ratiometric electrochemical immunosensor could detect CEA with good specificity within a wide linear range from 0.005ng/ml to 40ng/ml with a detection limit of 2.2pg/ml. Additionally, experimental results confirm that our proposed method is practical. Thus, this method can expand to recognize and test other protein markers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Antígeno Carcinoembrionário / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Antígeno Carcinoembrionário / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2016 Tipo de documento: Article