Your browser doesn't support javascript.
loading
An HPLC-MS method for the quantification of new acetylcholinesterase inhibitor PC 48 (7-MEOTA-donepezil like compound) in rat plasma: Application to a pharmacokinetic study.
Mzik, Martin; Korabecny, Jan; Nepovimova, Eugenie; Vorísek, Viktor; Palicka, Vladimir; Kuca, Kamil; Zdarova Karasova, Jana.
Afiliação
  • Mzik M; Institute of Clinical Biochemistry and Diagnostic, University Hospital, Hradec Kralove, Czech Republic.
  • Korabecny J; Department of Toxicology and Military Pharmacy, Faculty of Military Health Sciences, University of Defense, Hradec Kralove, Brno, Czech Republic.
  • Nepovimova E; Department of Toxicology and Military Pharmacy, Faculty of Military Health Sciences, University of Defense, Hradec Kralove, Brno, Czech Republic; Biomedical Research Center, University Hospital, Hradec Kralove, Czech Republic.
  • Vorísek V; Institute of Clinical Biochemistry and Diagnostic, University Hospital, Hradec Kralove, Czech Republic.
  • Palicka V; Institute of Clinical Biochemistry and Diagnostic, University Hospital, Hradec Kralove, Czech Republic.
  • Kuca K; Biomedical Research Center, University Hospital, Hradec Kralove, Czech Republic; Department of Cellular Biology and Pharmacology, College of Medicine, International University, Miami, FL, USA.
  • Zdarova Karasova J; Department of Toxicology and Military Pharmacy, Faculty of Military Health Sciences, University of Defense, Hradec Kralove, Brno, Czech Republic; Biomedical Research Center, University Hospital, Hradec Kralove, Czech Republic. Electronic address: zdarova.jana@gmail.com.
Article em En | MEDLINE | ID: mdl-27030895
ABSTRACT
A simple, rapid and sensitive method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative determination in rat plasma of a new candidate for AD treatment, namely PC 48 (a 7-MEOTA-donepezil like compound) in rat plasma. Sample preparation involved pH adjustment with sodium hydroxide followed by solvent extraction with ethyl acetatedichloromethane (8020, v/v). The chromatographic separation was achieved on an Ascentis Express RP-Amide column (75 mm × 2.1mm, 2.7 µm) with a gradient mobile phase consisting of 0.05 M aqueous formic acid and acetonitrile. Detection was carried out using positive-ion electrospray tandem mass spectrometry on an LTQ XL system using the MS/MS CID (collision-induced dissociation) mode. The method was linear in the range 0.1-1000 ng/ml (r(2)=0.999) with a lower limit of quantitation of 0.1 ng/mL. Extraction recovery was in the range 63.5-72.1% for PC 48 and 70.5% for reserpine (internal standard, IS). Intra- and inter-day precisions measured as relative standard deviation were below 10.8% and accuracy was from -7.2% to 7.4%. The method was successfully applied to a pharmacokinetic study involving intramuscular application of 3.86 mg/kg PC 48 to rats for the first time. Pharmacokinetic parameters for PC 48 include Cmax 39.09 ± 4.45 ng/mL,Tmax 5.00 ± 3.08 min, AUC0-t 23374 ± 4045 min ng/mL and t1/2 1065 ± 246 min.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Tacrina / Inibidores da Colinesterase / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Indanos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Tacrina / Inibidores da Colinesterase / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Indanos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2016 Tipo de documento: Article