Your browser doesn't support javascript.
loading
Incremental value of thoracic ultrasound in intensive care units: Indications, uses, and applications.
Liccardo, Biagio; Martone, Francesca; Trambaiolo, Paolo; Severino, Sergio; Cibinel, Gian Alfonso; D'Andrea, Antonello.
Afiliação
  • Liccardo B; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
  • Martone F; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
  • Trambaiolo P; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
  • Severino S; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
  • Cibinel GA; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
  • D'Andrea A; Biagio Liccardo, Francesca Martone, Sergio Severino, Antonello D'Andrea, Second University of Naples, AORN "dei Colli", Monaldi Hospital, 80122 Naples, Italy.
World J Radiol ; 8(5): 460-71, 2016 May 28.
Article em En | MEDLINE | ID: mdl-27247712
ABSTRACT
Emergency physicians are required to care for unstable patients with life-threatening conditions, and thus must make decisions that are both quick and precise about unclear clinical situations. There is increasing consensus in favor of using ultrasound as a real-time bedside clinical tool for clinicians in emergency settings alongside the irreplaceable use of historical and physical examinations. B-mode sonography is an old technology that was first proposed for medical applications more than 50 years ago. Its application in the diagnosis of thoracic diseases has always been considered limited, due to the presence of air in the lung and the presence of the bones of the thoracic cage, which prevent the progression of the ultrasound beam. However, the close relationship between air and water in the lungs causes a variety of artifacts on ultrasounds. At the bedside, thoracic ultrasound is based primarily on the analysis of these artifacts, with the aim of improving accuracy and safety in the diagnosis and therapy of the various varieties of pulmonary pathologic diseases which are predominantly "water-rich" or "air-rich". The indications, contraindications, advantages, disadvantages, and techniques of thoracic ultrasound and its related procedures are analyzed in the present review.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: World J Radiol Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: World J Radiol Ano de publicação: 2016 Tipo de documento: Article