Your browser doesn't support javascript.
loading
Three-Year Outcomes With the Multilayer Flow Modulator for Repair of Thoracoabdominal Aneurysms: A Follow-up Report From the STRATO Trial.
Vaislic, Claude D; Fabiani, Jean Noël; Chocron, Sidney; Robin, Jacques; Costache, Victor S; Villemot, Jean-Pierre; Alsac, Jean Marc; Leprince, Pascal N; Unterseeh, Thierry; Portocarrero, Eric; Glock, Yves; Rousseau, Hervé.
Afiliação
  • Vaislic CD; Department of Cardiac, Vascular, and Thoracic Surgery, Centre Hospitalier Privé Parly 2, Le Chesnay, France claudevaislic@hotmail.com.
  • Fabiani JN; Department of Cardiovascular Surgery, Hôpital Européen Georges-Pompidou, Paris, France.
  • Chocron S; Department of Thoracic and Cardiovascular Surgery, Hôpital Jean Minjoz, Besançon, France.
  • Robin J; Department of Cardiovascular Surgery, Hôpital Louis Pradel, Lyon-Bron, France.
  • Costache VS; Department of Cardiac Surgery, Centre Hospitalier de la Région d'Annecy, Metz-Tessy, France.
  • Villemot JP; Department of Cardiovascular Surgery and Transplantation, CHU-Nancy, Hôpital d'adultes de Brabois, Nancy, France.
  • Alsac JM; Department of Cardiovascular Surgery, Hôpital Européen Georges-Pompidou, Paris, France.
  • Leprince PN; Department of Thoracic and Cardiovascular Surgery, Hôpital Pitié-Salpétrière, Paris, France.
  • Unterseeh T; Department of Interventional Cardiology, Institut Cardiovasculaire Paris Sud, Hôpital Privé Claude Galien, Quincy-sous-Sénart, France.
  • Portocarrero E; Department of Cardiovascular Surgery and Transplantation, CHU-Nancy, Hôpital d'adultes de Brabois, Nancy, France.
  • Glock Y; Department of Cardiovascular Surgery, CHU Toulouse, Hôpital Rangueil, Toulouse, France.
  • Rousseau H; Department of Radiology, CHU Toulouse, Hôpital Rangueil, Toulouse, France.
J Endovasc Ther ; 23(5): 762-72, 2016 10.
Article em En | MEDLINE | ID: mdl-27280802
PURPOSE: To evaluate midterm outcomes of endovascular repair of types II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients unsuitable for open surgery or fenestrated stent-grafts. METHODS: In the prospective, multicenter, nonrandomized STRATO trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (mean age 75.8 years; 19 men) with Crawford type II and III TAAA (mean diameter 6.5 cm) were implanted between April 2010 and February 2011. Outcomes included all-cause mortality and stable aneurysm thrombosis with associated branch vessel patency. RESULTS: Through 36 months, there were 7 deaths (none confirmed as aneurysm-related), and no cases of spinal cord injury, device migration or fracture, or respiratory, renal, or peripheral complications. Three patients were lost to follow-up and 2 devices were explanted. The device was patent in the 11 remaining patients at 3 years. Stable aneurysm thrombosis was achieved for 15 of 20 patients at 12 months, 12 of 13 at 24 months, and 10 of 11 at 36 months. The rate of branch patency was 96% at 12 months (primary patency), 100% at 24 months, and 97% at 36 months. Nine patients suffered from endoleaks (attachment site or device overlap); 9 patients underwent 11 reinterventions (3 surgical). Maximum aneurysm diameter was stable for 18 of 20 patients at 12 months, 11 of 13 at 24 months, and 9 of 11 at 36 months. For 10 patients with computed tomography at 36 months, the mean ratio of aneurysm flow volume to total volume had decreased by 83%; the mean ratio of thrombus volume to total volume increased by 159%. CONCLUSION: Through 3 years, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Endovasc Ther Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Aneurisma da Aorta Torácica / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Clinical_trials / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: Europa Idioma: En Revista: J Endovasc Ther Ano de publicação: 2016 Tipo de documento: Article