Your browser doesn't support javascript.
loading
ASPECTS (Alberta Stroke Program Early CT Score) Assessment of the Perfusion-Diffusion Mismatch.
Lassalle, Louis; Turc, Guillaume; Tisserand, Marie; Charron, Sylvain; Roca, Pauline; Lion, Stephanie; Legrand, Laurence; Edjlali, Myriam; Naggara, Olivier; Meder, Jean-François; Mas, Jean-Louis; Baron, Jean-Claude; Oppenheim, Catherine.
Afiliação
  • Lassalle L; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Turc G; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Tisserand M; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Charron S; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Roca P; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Lion S; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Legrand L; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Edjlali M; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Naggara O; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Meder JF; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Mas JL; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Baron JC; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
  • Oppenheim C; From the Departments of Radiology (L. Lassalle, M.T., S.C., P.R., S.L., L. Legrand, M.E., O.N., J.-F.M., C.O.), and Neurology (G.T., J.-L.M., J.-C.B.), Université Paris Descartes Sorbonne Paris Cité, Centre de Psychiatrie et Neurosciences, INSERM S894, DHU Neurovasc, Centre Hospitalier Sainte-Anne,
Stroke ; 47(10): 2553-8, 2016 10.
Article em En | MEDLINE | ID: mdl-27625381
ABSTRACT
BACKGROUND AND

PURPOSE:

Rapid and reliable assessment of the perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch is required to promote its wider application in both acute stroke clinical routine and trials. We tested whether an evaluation based on the Alberta Stroke Program Early CT Score (ASPECTS) reliably identifies the PWI/DWI mismatch.

METHODS:

A total of 232 consecutive patients with acute middle cerebral artery stroke who underwent pretreatment magnetic resonance imaging (PWI and DWI) were retrospectively evaluated. PWI-ASPECTS and DWI-ASPECTS were determined blind from manually segmented PWI and DWI volumes. Mismatch-ASPECTS was defined as the difference between PWI-ASPECTS and DWI-ASPECTS (a high score indicates a large mismatch). We determined the mismatch-ASPECTS cutoff that best identified the volumetric mismatch, defined as VolumeTmax>6s/VolumeDWI≥1.8, a volume difference≥15 mL, and a VolumeDWI<70 mL.

RESULTS:

Inter-reader agreement was almost perfect for PWI-ASPECTS (κ=0.95 [95% confidence interval, 0.90-1]), and DWI-ASPECTS (κ=0.96 [95% confidence interval, 0.91-1]). There were strong negative correlations between volumetric and ASPECTS-based assessments of DWI lesions (ρ=-0.84, P<0.01) and PWI lesions (ρ=-0.90, P<0.01). Receiver operating characteristic curve analysis showed that a mismatch-ASPECTS ≥2 best identified a volumetric mismatch, with a sensitivity of 0.93 (95% confidence interval, 0.89-0.98) and a specificity of 0.82 (95% confidence interval, 0.74-0.89).

CONCLUSIONS:

The mismatch-ASPECTS method can detect a true mismatch in patients with acute middle cerebral artery stroke. It could be used for rapid screening of patients with eligible mismatch, in centers not equipped with ultrafast postprocessing software.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Isquemia Encefálica / Infarto da Artéria Cerebral Média / Imagem de Difusão por Ressonância Magnética / Imagem de Perfusão Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Stroke Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Isquemia Encefálica / Infarto da Artéria Cerebral Média / Imagem de Difusão por Ressonância Magnética / Imagem de Perfusão Tipo de estudo: Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Stroke Ano de publicação: 2016 Tipo de documento: Article