Your browser doesn't support javascript.
loading
Is Sonographic Assessment of Intratendinous Blood Flow in Achilles Tendinopathy Patients Reliable?: Consistency of Doppler Ultrasound Modes and Intra- and Inter-observer Reliability.
Risch, L; Cassel, M; Messerschmidt, J; Intziegianni, K; Fröhlich, K; Kopinski, S; Mayer, F.
Afiliação
  • Risch L; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Cassel M; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Messerschmidt J; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Intziegianni K; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Fröhlich K; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Kopinski S; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
  • Mayer F; University Outpatient Clinic, Sports Medicine and Sports Orthopaedics, University of Potsdam, Potsdam, Germany.
Ultrasound Int Open ; 2(1): E13-8, 2016 Mar.
Article em En | MEDLINE | ID: mdl-27689161
ABSTRACT

PURPOSE:

The purpose of this study was to investigate the consistency between different Doppler ultrasound (DU) modes as well as the intra- and inter-observer reliability of investigators with different experience level in assessing intratendinous blood flow (IBF) in Achilles tendinopathy patients. MATERIAL AND

METHODS:

18 participants (36 Achilles tendons, AT) with Achilles tendinopathy (24 AT) were examined with power Doppler ultrasound (PDU), colour Doppler ultrasound (CDU) and "Advanced Dynamic Flow" (ADF) (Toshiba Xario SSA-660 A; 14MHz transducer) by 2 investigators (experienced, EI; inexperienced, II) in a test-retest design (M1/M2). A modified Öhberg score was used to quantify IBF. Data was analysed descriptively (absolute and relative). Consistency of the 3 modes was presented by Kendall's Coefficient of Concordance (Kendall's W). Intra- and inter-observer reliability were calculated by use of Kendall's tau b correlation coefficient.

RESULTS:

IBF was detected in 79-92% of symptomatic AT and in 33-50% of contralateral asymptomatic AT. Comparing the 3 modes, Kendall's W ranged from 0.97-0.98. Analysis of intra-observer reliability resulted in Kendall's tau 0.90-0.92 for EI and 0.84-0.87 for II. Inter-observer reliability resulted in Kendall's tau 0.64-0.69 in M1 and 0.68-0.70 in M2.

CONCLUSION:

The very good consistency between PDU, CDU and ADF indicates a comparable applicability for assessing IBF in ATs. Intra-observer reliability was high for both investigators, independent of experience. The moderate inter-observer reliability reflects the challenge in sonographic detection of intratendinous blood flow (IBF) amount.