Your browser doesn't support javascript.
loading
Simultaneous analysis of 35 specific antihypertensive adulterants in dietary supplements using LC/MS/MS.
Heo, Seok; Choi, Ji Yeon; Yoo, Geum Joo; Park, Sung-Kwan; Baek, Sun Young.
Afiliação
  • Heo S; Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.
  • Choi JY; Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.
  • Yoo GJ; Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.
  • Park SK; Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.
  • Baek SY; Advanced Analysis Team, National Institute of Food and Drug Safety Evaluation, Ministry of Food and Drug Safety, Osong Health Technology Administration Complex, Cheongju-si, Cheongwoungcheongbuk-do, Republic of Korea.
Biomed Chromatogr ; 31(4)2017 Apr.
Article em En | MEDLINE | ID: mdl-27716982
ABSTRACT
A sensitive and specific LC/MS/MS method was developed for the simultaneous analysis of 35 compounds used for treating hypertension as adulterants in dietary supplements. The method was validated for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation, stability and recovery. The limit of detection and limit of quantitation ranged from 0.20 to 20.0 and 0.50 to 60.0 ng/g, respectively. The linearity was good (r2 > 0.999), with intra- and interday precision levels of 0.43-7.87% and 0.65-9.95% and the intra- and interday accuracies of 84.36-115.82% and 83.78-118.69%, respectively. The stability (relative standard deviation) was <14.75%. The mean recovery was 80.81-117.86% (relative standard deviation <10.00%). Ninety-seven commercial dietary supplements available in South Korea were analyzed. While none contained detectable amounts of the 35 antihypertensive compounds, the developed LC/MS/MS procedure can be used for routine analysis to monitor illegal adulteration in various forms of dietary supplements.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Suplementos Nutricionais / Anti-Hipertensivos Tipo de estudo: Diagnostic_studies País/Região como assunto: Asia Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Suplementos Nutricionais / Anti-Hipertensivos Tipo de estudo: Diagnostic_studies País/Região como assunto: Asia Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2017 Tipo de documento: Article