Your browser doesn't support javascript.
loading
Binocular function changes produced in response to overnight orthokeratology.
Felipe-Marquez, Gema; Nombela-Palomo, María; Palomo-Álvarez, Catalina; Cacho, Isabel; Nieto-Bona, Amelia.
Afiliação
  • Felipe-Marquez G; Department of Optics II (Optometry & Vision) Faculty of Optics & Optometry, Complutense University of Madrid, Arcos de Jalon 118, 28037, Madrid, Spain. gemafelipe@gmail.com.
  • Nombela-Palomo M; Department of Optics II (Optometry & Vision) Faculty of Optics & Optometry, Complutense University of Madrid, Arcos de Jalon 118, 28037, Madrid, Spain.
  • Palomo-Álvarez C; Applied Vision Research Group, Department of Optics II (Optometry & Vision) Faculty of Optics & Optometry, Complutense University of Madrid, Madrid, Spain.
  • Cacho I; Instituto Balear de Oftalmología, Balearic Islands, Palma, Spain.
  • Nieto-Bona A; Contactology and Optometry Research Group (GICO), Department of Optics II (Optometry & Vision) Faculty of Optics & Optometry, Complutense University of Madrid, Madrid, Spain.
Graefes Arch Clin Exp Ophthalmol ; 255(1): 179-188, 2017 Jan.
Article em En | MEDLINE | ID: mdl-27873014
ABSTRACT

PURPOSE:

To analyze the binocular function changes produced on subjects undergoing overnight orthokeratology (OK) treatment over short-term (3 months) and long-term (3 years) wear.

METHODS:

A prospective, longitudinal study on young adult subjects with low to moderate myopia was carried out. Binocular function was assessed by the following sequence of tests Distance and near horizontal phoria (Von Graefe technique), distance and near horizontal vergence ranges (Risley rotary prisms), accommodative convergence/accommodation (AC/A) ratio (gradient method) and the near point of convergence (standard push-up technique). The short-term sample consisted of 21 subjects in the control group, 26 in a corneal refractive therapy (CRT) treatment lenses group and 25 in a Seefree treatment lenses group. Those subjects were evaluated at baseline and at a 3-month follow-up visit. Twenty one subjects were old CRT wearers that attended a 3-year follow-up visit (long-term group).

RESULTS:

A statistically significant difference over the 3-month treatment was found for divergence at distance the break point decreased 1.4 Δ (p = 0.0006) in the CRT group and the recovery point increased 1.2 Δ (p = 0.001) in the Seefree group. Also, the Seefree group had an exophoric trend of 2.3 Δ at near (p = 0.02) and a base-out break decrease of 2.3 Δ (p = 0.03). For the long-term group, only the base-out break point at distant vision showed a statistically significant difference of 4.9 Δ (p = 0.02).

CONCLUSIONS:

OK induces minimal changes in the binocular function for either short-term or long-term periods, apart from a near exophoric trend over the short-term period.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Visão Binocular / Exotropia / Procedimentos Ortoceratológicos / Miopia Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Visão Binocular / Exotropia / Procedimentos Ortoceratológicos / Miopia Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2017 Tipo de documento: Article