Parameters That Improve Cleaning Efficiency of Subgingival Air Polishing on Titanium Implant Surfaces: An In Vitro Study.
Tastepe, Ceylin S; Lin, Xingnan; Donnet, Marcel; Wismeijer, Daniel; Liu, Yuelian.
Afiliação
  • Tastepe CS; Department of Oral Function and Restorative Dentistry, Section of Oral Implantology and Prosthodontics, Academic Center for Dentistry Amsterdam, Research Institute MOVE, Amsterdam, Netherlands.
  • Lin X; Department of Oral Function and Restorative Dentistry, Section of Oral Implantology and Prosthodontics, Academic Center for Dentistry Amsterdam, Research Institute MOVE, Amsterdam, Netherlands.
  • Donnet M; Department of Orthodontics, Affiliated Stomatological Hospital of Medical School, Nanjing University, Nanjing, China.
  • Wismeijer D; Research Group Dental, E.M.S. Electro Medical Systems S.A., Nyon, Switzerland.
  • Liu Y; Department of Oral Function and Restorative Dentistry, Section of Oral Implantology and Prosthodontics, Academic Center for Dentistry Amsterdam, Research Institute MOVE, Amsterdam, Netherlands.
J Periodontol ; 88(4): 407-414, 2017 04.
Article em En | MEDLINE | ID: mdl-27885965
ABSTRACT

BACKGROUND:

This study aims to reveal how air polishing behaves on a titanium surface by evaluating the size and shape of the cleaned area and the influence of different device settings, probing depths, and cleaning movements.

METHODS:

Forty-eight titanium sandblasted large-grit acid-etched surface film-coated disks were treated with an air abrasive system using a subgingival plastic nozzle. Two subgingival models were used open-ended (step 1) and defined-size (step 2). In step 1, the most effective parameters were investigated by 5-second static applications under different settings. In step 2, the best settings were used for dynamic application to test influence of different movements (up-down, slowly up, rotation). For both steps, powder and water consumption and total cleaned area were calculated.

RESULTS:

Air pressure was the main factor with the strongest effect on cleaning. Increasing air pressure extended cleaning area. Other factors, such as nozzle depth and excessive powder flow amount, had weak influence. Cleaning effect reached deeper than the nozzle physically reached. Step 2 showed that there was no significant difference between different nozzle movements; however, cleaning efficiency decreased significantly without movement.

CONCLUSIONS:

For the most effective clinical use of air polishing, it should be applied with high pressure, deep insertion of nozzle, and enough water flow. Additionally, the nozzle has to be moved to get the best cleaning effect.