Baxter elastomeric pumps: Weighing as an alternative to visual inspection.
Cusano, Ellen L; Ali, Raafi; Sawyer, Michael B; Chambers, Carole R; Tang, Patricia A.
Afiliação
  • Cusano EL; 1 Faculty of Medicine, University of Ottawa, ON, Canada.
  • Ali R; 2 Cross Cancer Institute and University of Alberta, Edmonton, AB, Canada.
  • Sawyer MB; 2 Cross Cancer Institute and University of Alberta, Edmonton, AB, Canada.
  • Chambers CR; 3 Cancer Services, Alberta Health Services, Calgary, AB, Canada.
  • Tang PA; 4 Tom Baker Cancer Centre and University of Calgary, Calgary, AB, Canada.
J Oncol Pharm Pract ; 24(3): 163-169, 2018 Apr.
Article em En | MEDLINE | ID: mdl-28077048
ABSTRACT
Purpose Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Percepção Visual / Pesos e Medidas / Bombas de Infusão / Fluoruracila Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: En Revista: J Oncol Pharm Pract Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Percepção Visual / Pesos e Medidas / Bombas de Infusão / Fluoruracila Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: En Revista: J Oncol Pharm Pract Ano de publicação: 2018 Tipo de documento: Article