Your browser doesn't support javascript.
loading
TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING.
Gómez-Ros, J M; Bedogni, R; Bortot, D; Domingo, C; Esposito, A; Introini, M V; Lorenzoli, M; Mazzitelli, G; Moraleda, M; Pola, A; Sacco, D.
Afiliação
  • Gómez-Ros JM; CIEMAT, Av. Complutense 40, 28040 Madrid, Spain.
  • Bedogni R; IFNF-LNF Laboratori Nazionali di Frascati, via E. Fermi n. 40, 00044 Frascati, Italy.
  • Bortot D; IFNF-LNF Laboratori Nazionali di Frascati, via E. Fermi n. 40, 00044 Frascati, Italy.
  • Domingo C; Politecnico di Milano-Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano, Italy.
  • Esposito A; UAB, Physics Department, 08193 Bellaterra, Spain.
  • Introini MV; IFNF-LNF Laboratori Nazionali di Frascati, via E. Fermi n. 40, 00044 Frascati, Italy.
  • Lorenzoli M; Politecnico di Milano-Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano, Italy.
  • Mazzitelli G; Politecnico di Milano-Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano, Italy.
  • Moraleda M; IFNF-LNF Laboratori Nazionali di Frascati, via E. Fermi n. 40, 00044 Frascati, Italy.
  • Pola A; CIEMAT, Av. Complutense 40, 28040 Madrid, Spain.
  • Sacco D; Politecnico di Milano-Dipartimento di Energia, Via Ponzio 34/3, 20133 Milano, Italy.
Radiat Prot Dosimetry ; 173(1-3): 104-110, 2017 Apr 01.
Article em En | MEDLINE | ID: mdl-28100670
This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold the neutron spectrum (from thermal to hundreds of MeV) and to determine the corresponding integral quantities with only one exposure. This makes them especially advantageous for neutron field characterisation and workplace monitoring in neutron-producing facilities. One of the devices has spherical geometry and nearly isotropic response, the other one has cylindrical symmetry and it is only sensitive to neutrons incident along the cylinder axis. In both cases, active detectors have been specifically developed looking for the criteria of miniaturisation, high sensitivity, linear response and good photon rejection. The calculated response matrix has been validated by experimental irradiations in neutron reference fields with a global uncertainty of 3%. The measurements performed in realistic neutron fields permitted to determine the neutron spectra and the integral quantities, in particular H*(10).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação / Local de Trabalho Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Monitoramento de Radiação / Local de Trabalho Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2017 Tipo de documento: Article