Your browser doesn't support javascript.
loading
[Results of residual ametropia correction using CIRCLE technology after femtosecond laser SMILE surgery]. / Rezul'taty ustraneniya ostatochnoi ametropii metodom CIRCLE posle lazernykh operatsii po tekhnologii SMILE.
Kostin, O A; Rebrikov, S V; Ovchinnikov, A I; Stepanov, A A; Takhchidi, Kh P.
Afiliação
  • Kostin OA; Ekaterinburg branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', 4A Akademika Bardina, Ekaterinburg, Sverdlovskaya Oblast, 620149.
  • Rebrikov SV; Ekaterinburg branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', 4A Akademika Bardina, Ekaterinburg, Sverdlovskaya Oblast, 620149.
  • Ovchinnikov AI; Ekaterinburg branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', 4A Akademika Bardina, Ekaterinburg, Sverdlovskaya Oblast, 620149.
  • Stepanov AA; Ekaterinburg branch of the Academician S.N. Fyodorov IRTC 'Eye Microsurgery', 4A Akademika Bardina, Ekaterinburg, Sverdlovskaya Oblast, 620149.
  • Takhchidi KP; Pirogov Russian National Research Medical University, 1 Ostrovityanova St., Moscow, Russian Federation, 117997.
Vestn Oftalmol ; 133(1): 55-59, 2017.
Article em Ru | MEDLINE | ID: mdl-28291201
ABSTRACT

AIM:

to evaluate functional results of reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser in cases of regression of the refractive effect after SMILE surgery. MATERIAL AND

METHODS:

We studied a group of post-SMILE patients. In those, who showed regression of the refractive effect at 1 year, reoperation was performed according to the CIRCLE technology and using the VisuMax femtosecond laser. The corneal flap was separated from the stromal bed and turned aside. Excimer laser ablation of the stromal bed was performed with the MEL 80 machine. The corneal flap was then placed back and rinsed from both sides. Uncorrected (UCVA) and corrected (BCVA) visual acuity as well as spherical equivalent (SE) were estimated before reoperation, on day 1, and at 1 month.

RESULTS:

After reoperation, BCVA and UCVA improved. Patient refraction became close to emmetropia. Specifically, UCVA was 0.23±0.18 at baseline (i.e. 1 year after SMILE) and 0.93±0.11 after the CIRCLE procedure (p<0.05). The absolute value of SE was 1.86±1.15 D and 0±0 D before and after CIRCLE, respectively (p<0.05). BCVA change was not statistically significant - from 0.95±0.1 to 0.93±0.11 (p>0.05).

CONCLUSION:

Reoperation performed according to the CIRCLE technology and using the VisuMax femtosecond laser and MEL-80 excimer laser provides an increase in visual acuity in case of post-SMILE regression of the refractive effect.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Erros de Refração / Transplante de Córnea / Terapia a Laser / Procedimentos Cirúrgicos Refrativos / Lasers de Excimer Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Female / Humans / Male Idioma: Ru Revista: Vestn Oftalmol Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Erros de Refração / Transplante de Córnea / Terapia a Laser / Procedimentos Cirúrgicos Refrativos / Lasers de Excimer Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Adult / Female / Humans / Male Idioma: Ru Revista: Vestn Oftalmol Ano de publicação: 2017 Tipo de documento: Article