Your browser doesn't support javascript.
loading
An LC/MS Method Providing Improved Sensitivity: Electrospray Ionization Inlet.
Fenner, Madeline A; Chakrabarty, Shubhashis; Wang, Beixi; Pagnotti, Vincent S; Hoang, Khoa; Trimpin, Sarah; McEwen, Charles N.
Afiliação
  • Fenner MA; Department of Chemistry & Biochemistry, University of the Sciences , Philadelphia, Pennsylvania 19104, United States.
  • Chakrabarty S; Department of Chemistry, Wayne State University , Detroit, Michigan 48202, United States.
  • Wang B; Department of Chemistry, Wayne State University , Detroit, Michigan 48202, United States.
  • Pagnotti VS; Department of Chemistry & Biochemistry, University of the Sciences , Philadelphia, Pennsylvania 19104, United States.
  • Hoang K; Department of Chemistry & Biochemistry, University of the Sciences , Philadelphia, Pennsylvania 19104, United States.
  • Trimpin S; Department of Chemistry, Wayne State University , Detroit, Michigan 48202, United States.
  • McEwen CN; MSTM, LLC , Newark, Delaware 19711, United States.
Anal Chem ; 89(9): 4798-4802, 2017 05 02.
Article em En | MEDLINE | ID: mdl-28387502
Electrospray ionization inlet (ESII) combines positive aspects of electrospray ionization (ESI) and solvent-assisted ionization (SAI). Similar to SAI, the analyte solution is directly introduced into a heated inlet tube linking atmospheric pressure and the initial vacuum stage of the mass spectrometer. However, unlike SAI, in ESII a voltage is applied to the solution through a metal union linking two sections of fused silica tubing through which solution flows into the inlet. Here, we demonstrate liquid chromatography (LC) ESII/MS on two different mass spectrometers using a mixture of drugs, a peptide standard mixture, and protein digests. This LC-ESII/MS approach has little dead volume and thus provides excellent chromatographic resolution at mobile phase flow rates from 1 to 55 µL min-1. Significant improvement in ion abundance and less chemical background ions were observed relative to ESI for all drugs and peptides tested at flow rates from 15 to 55 µL min-1. At a low inlet tube temperature, ESII has an ionization selectivity similar to that of ESI but, at higher inlet temperatures, appears to have the attributes of both ESI and SAI.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2017 Tipo de documento: Article