Your browser doesn't support javascript.
loading
LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies.
Coufalíková, Katerina; Benesová, Iva; Vaculovic, Tomás; Kanický, Viktor; Preisler, Jan.
Afiliação
  • Coufalíková K; Department of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic.
  • Benesová I; Department of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic; Central European Institute of Technology, CEITEC MU, Masaryk University, Brno, Czech Republic.
  • Vaculovic T; Department of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic; Central European Institute of Technology, CEITEC MU, Masaryk University, Brno, Czech Republic.
  • Kanický V; Department of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic; Central European Institute of Technology, CEITEC MU, Masaryk University, Brno, Czech Republic.
  • Preisler J; Department of Chemistry, Faculty of Science, Masaryk University, Brno, Czech Republic; Central European Institute of Technology, CEITEC MU, Masaryk University, Brno, Czech Republic. Electronic address: preisler@chemi.muni.cz.
Anal Chim Acta ; 968: 58-65, 2017 May 22.
Article em En | MEDLINE | ID: mdl-28395775
ABSTRACT
A new multiple detection arrangement for liquid chromatography (LC) that supplements conventional electrospray ionization (ESI) mass spectrometry (MS) detection with two complementary detection techniques, matrix-assisted laser desorption/ionization (MALDI) MS and substrate-assisted laser desorption inductively coupled plasma (SALD ICP) MS has been developed. The combination of the molecular and elemental detectors in a single separation run is accomplished by utilizing a commercial MALDI target made of conductive plastic. The proposed platform provides a number of benefits in today's metalloproteomic applications, which are demonstrated by analysis of a metallothionein mixture. To maintain metallothionein complexes, separation is carried out at a neutral pH. The effluent is split; a major portion is directed to ESI MS while the remaining 1.8% fraction is deposited onto a plastic MALDI target. Dried droplets are overlaid with MALDI matrix and analysed consecutively by MALDI MS and SALD ICP MS. In the ESI MS spectra, the MT isoform complexes with metals and their stoichiometry are determined; the apoforms are revealed in the MALDI MS spectra. Quantitative determination of metallothionein isoforms is performed via determination of metals in the complexes of the individual protein isoforms using SALD ICP MS.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas por Ionização por Electrospray / Proteômica / Metalotioneína Idioma: En Revista: Anal Chim Acta Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas por Ionização por Electrospray / Proteômica / Metalotioneína Idioma: En Revista: Anal Chim Acta Ano de publicação: 2017 Tipo de documento: Article