Your browser doesn't support javascript.
loading
Calibration and characterization of a highly efficient spectrometer in von Hamos geometry for 7-10 keV x-rays.
Jarrott, L C; Wei, M S; McGuffey, C; Beg, F N; Nilson, P M; Sorce, C; Stoeckl, C; Theoboald, W; Sawada, H; Stephens, R B; Patel, P K; McLean, H S; Landen, O L; Glenzer, S H; Döppner, T.
Afiliação
  • Jarrott LC; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Wei MS; General Atomics, San Diego, California 92121, USA.
  • McGuffey C; University of California at San Diego, La Jolla, California 92093, USA.
  • Beg FN; University of California at San Diego, La Jolla, California 92093, USA.
  • Nilson PM; Laboratory for Laser Energetics, Rochester, New York 14623, USA.
  • Sorce C; Laboratory for Laser Energetics, Rochester, New York 14623, USA.
  • Stoeckl C; Laboratory for Laser Energetics, Rochester, New York 14623, USA.
  • Theoboald W; Laboratory for Laser Energetics, Rochester, New York 14623, USA.
  • Sawada H; Department of Physics, University of Nevada, Reno, Nevada 89557, USA.
  • Stephens RB; General Atomics, San Diego, California 92121, USA.
  • Patel PK; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • McLean HS; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Landen OL; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Glenzer SH; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Döppner T; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
Rev Sci Instrum ; 88(4): 043110, 2017 Apr.
Article em En | MEDLINE | ID: mdl-28456236
ABSTRACT
We have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7-10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experiments in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article