  • Uri A; Institute of Chemistry, University of Tartu, 14A Ravila St., 50411 Tartu, Estonia. Electronic address: asko.uri@ut.ee.
Anal Biochem ; 531: 67-77, 2017 08 15.
Article em En | MEDLINE | ID: mdl-28527909
ABSTRACT
High demand for inhibitors regulating the activity of protein kinases has stimulated the quest for high throughput and reliable compound screening assays. Here we introduce a method applying a non-metal photoluminescent probe ARC-Lum(Fluo) for determination of dissociation constants of competitive inhibitors of protein kinases. Employing a single probe instead of a combination of antibody and fluorescent tracer makes the assay simpler, cheaper, and more accurate than several other inhibitor-screening technologies. High affinity (20 pM) and low background signal of the free probe supports the determination of dissociation constants of tight-binding as well as low affinity inhibitors. The calculated lowest Kd value that can be accurately determined with the method is 60 fM. We also introduce graphical presentation of the linearized Cheng-Prusoff equation and demonstrate multiple possibilities for its application (deciding upon the assay formats, calculation of the limits of Kd determination, etc.). The open toolbox (http//www.ut.ee/medchem/toolbox-fluorescence-probes) is available for creating the map of resolvable affinities if applying the competitive probes at defined assay conditions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Proteínas Quinases Dependentes de AMP Cíclico / Inibidores de Proteínas Quinases / Fluorescência Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Proteínas Quinases Dependentes de AMP Cíclico / Inibidores de Proteínas Quinases / Fluorescência Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2017 Tipo de documento: Article