Your browser doesn't support javascript.
loading
Impact of prior distributions and central tendency measures on Bayesian intravoxel incoherent motion model fitting.
Gustafsson, Oscar; Montelius, Mikael; Starck, Göran; Ljungberg, Maria.
Afiliação
  • Gustafsson O; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Montelius M; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Starck G; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Ljungberg M; Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Magn Reson Med ; 79(3): 1674-1683, 2018 03.
Article em En | MEDLINE | ID: mdl-28626964
ABSTRACT

PURPOSE:

Bayesian model fitting has been proposed as a robust alternative for intravoxel incoherent motion (IVIM) model-fitting parameter estimation. However, consensus regarding choice of prior distribution and posterior distribution central tendency measure is needed. The aim of this study was to compare the quality of IVIM parameter estimates produced by different prior distributions and central tendency measures, and to gain knowledge about the effect of these choices.

METHODS:

Three prior distributions (uniform, reciprocal, and lognormal) and two measures of central tendency (mean and mode) found in the literature were studied using simulations and in vivo data from a tumor mouse model.

RESULTS:

Simulations showed that the uniform and lognormal priors were superior to the reciprocal prior, especially for the parameters D and f and clinically relevant SNR levels. The choice of central tendency measure had less effect on the results, but had some effects on estimation bias. Results based on simulations and in vivo data agreed well, indicating high validity of the simulations.

CONCLUSIONS:

Choice of prior distribution and central tendency measure affects the results of Bayesian IVIM parameter estimates. This must be considered when comparing results from different studies. The best overall quality of IVIM parameter estimates was obtained using the lognormal prior. Magn Reson Med 791674-1683, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Teorema de Bayes Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Magn Reson Med Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Teorema de Bayes Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Magn Reson Med Ano de publicação: 2018 Tipo de documento: Article