Elevated IOP alters the space-time profiles in the center and surround of both ON and OFF RGCs in mouse.
Sabharwal, J; Seilheimer, R L; Tao, X; Cowan, C S; Frankfort, B J; Wu, S M.
Afiliação
  • Sabharwal J; Medical Scientist Training Program, Baylor College of Medicine, Houston, TX 77030; jsab1208@gmail.com.
  • Seilheimer RL; Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030.
  • Tao X; Department of Ophthalmology, Baylor College of Medicine, Houston, TX 77030.
  • Cowan CS; Medical Scientist Training Program, Baylor College of Medicine, Houston, TX 77030.
  • Frankfort BJ; Department of Ophthalmology, Baylor College of Medicine, Houston, TX 77030.
  • Wu SM; Department of Ophthalmology, Baylor College of Medicine, Houston, TX 77030.
Proc Natl Acad Sci U S A ; 114(33): 8859-8864, 2017 08 15.
Article em En | MEDLINE | ID: mdl-28760976
Glaucoma is a leading cause of blindness worldwide, and is characterized by progressive retinal ganglion cell (RGC) death. An experimental model of glaucoma has been established by elevating the intraocular pressure (IOP) via microbead occlusion of ocular fluid outflow in mice. Studies in this model have found visual dysfunction that varied with adaptational state, occurred before anatomical changes, and affected OFF RGCs more than ON RGCs. These results indicate subtle alterations in the underlying retinal circuitry that could help identify disease before irreversible RGC changes. Therefore, we looked at how RGC function was altered with elevated IOP under both photopic and scotopic conditions. We first found that responses to light offset are diminished with IOP elevation along with a concomitant decrease in receptive field center size for OFF RGCs. In addition, the antagonistic surround strength and size was reduced in ON RGCs. Furthermore, elevation of IOP significantly accelerated the photopic temporal tuning of RGC center responses in both ON and OFF RGCs. We found that some of the IOP-induced functional changes to OFF RGCs relied on ON cross-over pathways, indicating dysfunction in inner retinal circuitry. Overall, these results suggest that IOP alters multiple functions in the retina depending on the adaptational state. They provide a basis for designing multiple functional tests for early detection of glaucoma and for circuit-specific therapeutic targets in treatment of this blinding disease.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Humor Aquoso / Células Ganglionares da Retina / Glaucoma / Pressão Intraocular Tipo de estudo: Screening_studies Limite: Animals Idioma: En Revista: Proc Natl Acad Sci U S A Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Humor Aquoso / Células Ganglionares da Retina / Glaucoma / Pressão Intraocular Tipo de estudo: Screening_studies Limite: Animals Idioma: En Revista: Proc Natl Acad Sci U S A Ano de publicação: 2017 Tipo de documento: Article