Your browser doesn't support javascript.
loading
Surface-Engineered Blood Adsorption Device for Hyperphosphatemia Treatment.
Shi, Quan; Jolly, Michael; Mccord, Marian G; Joy, Melanie S.
Afiliação
  • Shi Q; From the Fiber and Polymer Science Program, Department of Textile Engineering, Chemistry and Science, North Carolina State University, Raleigh, NC.
  • Jolly M; From the Fiber and Polymer Science Program, Department of Textile Engineering, Chemistry and Science, North Carolina State University, Raleigh, NC.
  • Mccord MG; From the Fiber and Polymer Science Program, Department of Textile Engineering, Chemistry and Science, North Carolina State University, Raleigh, NC.
  • Joy MS; Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC and University of North Carolina, Chapel Hill, NC.
ASAIO J ; 64(3): 389-394, 2018.
Article em En | MEDLINE | ID: mdl-28799951
ABSTRACT
Correspondence Melanie S. Joy, PharmD, PhD, University of Colorado Skaggs School of Pharmacy and Pharmaceutical Sciences, Department of Pharmaceutical Sciences, Mail Stop C238, Room V20-4108, 12850 East Montview Blvd, Aurora, CO 80045. Email Melanie.Joy@ucdenver.edu The research employed surface engineering methods to develop, optimize, and characterize a novel textile-based hemoadsorption device for hyperphosphatemia in hemodialysis-dependent end-stage kidney disease. Phosphate adsorbent fabrics (PAFs) were prepared by thermopressing alumina powders to polyester filtration fabrics and treatment with trimesic acid (TMA). For static experiments, phosphate adsorption capacity in buffer solution, plasma, and blood were evaluated by submersing the PAFs in 100 ml. For dynamic experiments, PAFs were equipped in a device prototype and incorporated in a pump-driven circuit. Phosphates were determined by a colorimetric assay and an Ortho Clinical Diagnostics Vitros 5600 Integrated analyzer. The maximum loading amount of TMA-alumina on PAFs was approximately 35 g/m under 260°C processing temperature. Phosphate adsorption capacity increased with initial concentration. Adsorption isotherms from buffer demonstrated a maximum phosphate adsorption capacity of approximately 893 mg/m at 37.5°C, pH 7.4, with similar results from plasma and whole blood. Measured phosphate concentrations during simulations demonstrated a 42% reduction, confirming the high capacity of the PAFs for removing phosphate from whole blood. Results from the current study indicated that an alumina-TMA treated PAF can dramatically reduce phosphate concentrations from biological samples. The technology could potentially be used as a tunable adsorbent for managing hyperphosphatemia in kidney disease.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemoperfusão / Hiperfosfatemia / Membranas Artificiais Limite: Humans Idioma: En Revista: ASAIO J Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hemoperfusão / Hiperfosfatemia / Membranas Artificiais Limite: Humans Idioma: En Revista: ASAIO J Ano de publicação: 2018 Tipo de documento: Article