Your browser doesn't support javascript.
loading
Clinical features and prognosis of patients with isolated severe aortic stenosis and valve area less than 1.0 cm2.
Mehrotra, Praveen; Jansen, Katrijn; Tan, Timothy C; Flynn, Aidan; Hung, Judy W.
Afiliação
  • Mehrotra P; Division of Cardiology, Thomas Jefferson University Hospital and Sidney Kimmel Medical College, Philadelphia, Pennsylvania, USA.
  • Jansen K; Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Tan TC; Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Flynn A; Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Hung JW; Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Heart ; 104(3): 222-229, 2018 02.
Article em En | MEDLINE | ID: mdl-28814490
ABSTRACT

OBJECTIVE:

Current guidelines define severe aortic stenosis (AS) as an aortic valve area (AVA)≤1.0 cm2, but some authors have suggested that the AVA cut-off be decreased to 0.8 cm2. The aim of this study was, therefore, to better describe the clinical features and prognosis of patients with an AVA of 0.8-0.99 cm2.

METHODS:

Patients with isolated, severe AS and ejection fraction ≥55% with an AVA of 0.8-0.99 cm2 (n=105) were compared with those with an AVA<0.8 cm2 (n=155) and 1.0-1.3 cm2 (n=81). The endpoint of this study was a combination of death from any cause or aortic valve replacement at or before 3 years.

RESULTS:

Patients with an AVA of 0.8-0.99 cm2 group comprised predominantly normal-flow, low-gradient (NFLG) AS, while high gradients and low flow were more often observed with an AVA<0.8 cm2. The frequency of symptoms was not significantly different between an AVA of 0.8-0.99 cm2 and 1.0-1.3 cm2. The combined endpoint was achieved in 71%, 52% and 21% of patients with an AVA of 0.8 cm2, 0.8-0.99 cm2and 1.0-1.3 cm2, respectively (p<0.001). Among patients with an AVA of 0.8-0.99 cm2, NFLG AS was associated with a lower hazard (HR=0.40, 95% CI 0.23 to 0.68, p=0.001) of achieving the combined endpoint with outcomes similar to moderate AS in the first 1.5 years of follow-up. Patients with high-gradient or low-flow AS with an AVA of 0.8-0.99 cm2 had outcomes similar to those with an AVA<0.8 cm2. The sensitivity for the combined endpoint was 61% for an AVA cut-off of 0.8 cm2 and 91% for a cut-off of 1.0 cm2.

CONCLUSIONS:

The outcomes of patients with AS with an AVA of 0.8-0.99 cm2 are variable and are more precisely defined by flow-gradient status. Our findings support the current AVA cut-off of 1.0 cm2.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Heart Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 6_ODS3_enfermedades_notrasmisibles Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica Tipo de estudo: Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Heart Ano de publicação: 2018 Tipo de documento: Article