Your browser doesn't support javascript.
loading
Label-free photoelectrochemical immunoassay for CEA detection based on CdS sensitized WO3@BiOI heterostructure nanocomposite.
Han, Qingzhi; Wang, Rongyu; Xing, Bin; Zhang, Tong; Khan, Malik Saddam; Wu, Dan; Wei, Qin.
Afiliação
  • Han Q; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Wang R; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Xing B; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Zhang T; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Khan MS; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Wu D; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China. Electronic address: wudan791108@163.com.
  • Wei Q; Key Laboratory of Interfacial Reaction&Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
Biosens Bioelectron ; 99: 493-499, 2018 Jan 15.
Article em En | MEDLINE | ID: mdl-28823974
ABSTRACT
In this work, a label-free photoelectrochemical (PEC) immunosensor for the detection of carcino embryonic antigen (CEA) was developed based on CdS nanowires (NWs) sensitized WO3@BiOI heterostructure. The construction procedure of ITO/WO3@BiOI@CdS electrode was done by dipping the WO3@BiOI modified indium-tin oxide (ITO) electrode interchangeably into [Cd(NH3)4]2+ and S2- solution for several times. Then the ITO/WO3@BiOI@CdS electrode was used as a matrix for the subsequent immobilization of CEA antibody (Ab). The obtained label-free PEC immunosensor showed an excellent PEC performance toward CEA detection. Under optimal conditions, the PEC immunosensor have a sensitive response to CEA in a liner range of 0.01ng/mL to 50ng/mL with a detection limit of 3.2pg/mL. The proposed PEC immunosensor exhibited good stability, high sensitivity as well as reproducibility and storage stability. Moreover, the obtained PEC immunosensor also showed a satisfied result in human serum sample analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Carcinoembrionário / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Carcinoembrionário / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2018 Tipo de documento: Article