Your browser doesn't support javascript.
loading
Simultaneous optimization of pH and binary organic composition by grid form modeling of the retention behavior in reversed-phase ultra high-performance liquid chromatography.
Sasaki, Tsukasa; Todoroki, Kenichiro; Toyo'oka, Toshimasa.
Afiliação
  • Sasaki T; Laboratory of Analytical and Bio-Analytical Chemistry, Graduate Division of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Shizuoka, Suruga-Ku, Shizuoka 422-8526, Japan; Analytical and Quality Evaluation Research Laboratories, Daiichi Sankyo Co., Ltd., 1-12-1 Shinomiya, Hiratsuka, Kanagawa 254-0014, Japan. Electronic address: sasaki.tsukasa.ys@daiichisankyo.co.jp.
  • Todoroki K; Laboratory of Analytical and Bio-Analytical Chemistry, Graduate Division of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Shizuoka, Suruga-Ku, Shizuoka 422-8526, Japan. Electronic address: todoroki@u-shizuoka-ken.ac.jp.
  • Toyo'oka T; Laboratory of Analytical and Bio-Analytical Chemistry, Graduate Division of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Shizuoka, Suruga-Ku, Shizuoka 422-8526, Japan. Electronic address: toyooka@u-shizuoka-ken.ac.jp.
J Pharm Biomed Anal ; 146: 251-260, 2017 Nov 30.
Article em En | MEDLINE | ID: mdl-28888712
ABSTRACT
A novel computer-assisted methodology for the simultaneous optimization of aqueous pH and binary organic eluent composition through a broad range of analytical conditions of reversed-phase ultra high-performance liquid chromatography is proposed. Two of nonlinear prediction models were employed to fit into the retention time (tR) on a linear gradient elution with a predefined slope. One model was derived from Bernoulli-type probability distribution to predict the value of tR against the pH value of the aqueous eluent. This sigmoid-shaped model was successfully fitted for tR value shift in the presence of three levels of organic eluent compositions (volumetric mixing of acetonitrile/methanol ratios 10, 11, and 01). The resultant pH versus tR value models were subsequently combined into grid form by quadratic multiple regression models based on the solubility parameter theory and their binary organic composition axes. The predicted tR values afforded from grid models were highly accurate for 13 different acidic non-steroidal anti-inflammatory drugs [root mean square error (RMSE) ≤0.030] and 16 basic histamine H1-receptor blockers (RMSE ≤0.067) in a pH ranging from 2.5 to 9.0 and an acetonitrile/methanol volumetric mixing ratio ranging from 10 to 01. Each compatibility score was defined as the indicator of the peak separation. Scores were calculated for all combinations of aqueous pH values and binary organic compositions via the predicted tR values. A colored map generated from the calculated scores was greatly effective in determining optimal combinations of both mobile phase conditions. By employing this predictive data, all analytes in both acidic and basic sample mixtures were finally separated at their respective optimized conditions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Cromatografia de Fase Reversa Tipo de estudo: Prognostic_studies Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Cromatografia de Fase Reversa Tipo de estudo: Prognostic_studies Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2017 Tipo de documento: Article