Your browser doesn't support javascript.
loading
Preparation of hydrophilic blood compatible polypropylene/pluronics F127 films.
Hakani, Mahsa; Haddadi-Asl, Vahid; Zargarian, Seyed Shahrooz; Moghadasi, Mohamad Hossein.
Afiliação
  • Hakani M; Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran, Iran.
  • Haddadi-Asl V; Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran, Iran.
  • Zargarian SS; Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran, Iran.
  • Moghadasi MH; Department of Medical laboratory, Labbafinejad Hospital, Iranian Social Security Organization, Tehran, Iran.
J Biomed Mater Res A ; 106(3): 652-662, 2018 03.
Article em En | MEDLINE | ID: mdl-29027360
ABSTRACT
In order to improve surface hydrophilicity, blood compatibility and cell-antiadhesion of polypropylene (PP) film, polypropylene oxide (PPO)-polyethylene oxide-PPO used as macromolecular surface modifier through physical blending. Surface properties of blended PP/Pluronic F127 (PF127) samples were investigated by attenuated total reflection infrared spectroscopy and water contact angle measurements. Results demonstrated that PF127 migrated to the surface. Thus, mechanical properties of blended PP/PF127 samples with the aim of the revealing the effects of the presence of modifier in the bulk were investigated through differential scanning calorimetry, X-ray diffraction, and tensile tests. The biocompatibility and hemocompatibility of modified PP films were evaluated by 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, platelet-rich plasma, and hemolysis tests. These results showed excellent anticell and antiplatelet adhesion which deems the prepared blended films proper biomaterials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A 106A 652-662, 2018.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polipropilenos / Teste de Materiais / Poloxâmero / Interações Hidrofóbicas e Hidrofílicas Limite: Humans Idioma: En Revista: J Biomed Mater Res A Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polipropilenos / Teste de Materiais / Poloxâmero / Interações Hidrofóbicas e Hidrofílicas Limite: Humans Idioma: En Revista: J Biomed Mater Res A Ano de publicação: 2018 Tipo de documento: Article