Ultrasensitive and Selective Organic FET-type Nonenzymatic Dopamine Sensor Based on Platinum Nanoparticles-Decorated Reduced Graphene Oxide.
Oh, Jungkyun; Lee, Jun Seop; Jun, Jaemoon; Kim, Sung Gun; Jang, Jyongsik.
Afiliação
  • Oh J; School of Chemical and Biological Engineering, College of Engineering, Seoul National University (SNU) , 599 Gwanangno, Gwanak-gu, Seoul 151-742, Korea.
  • Lee JS; School of Chemical and Biological Engineering, College of Engineering, Seoul National University (SNU) , 599 Gwanangno, Gwanak-gu, Seoul 151-742, Korea.
  • Jun J; School of Chemical and Biological Engineering, College of Engineering, Seoul National University (SNU) , 599 Gwanangno, Gwanak-gu, Seoul 151-742, Korea.
  • Kim SG; School of Chemical and Biological Engineering, College of Engineering, Seoul National University (SNU) , 599 Gwanangno, Gwanak-gu, Seoul 151-742, Korea.
  • Jang J; School of Chemical and Biological Engineering, College of Engineering, Seoul National University (SNU) , 599 Gwanangno, Gwanak-gu, Seoul 151-742, Korea.
ACS Appl Mater Interfaces ; 9(45): 39526-39533, 2017 Nov 15.
Article em En | MEDLINE | ID: mdl-29067802
ABSTRACT
Dopamine (DA), a catecholamine hormone, is an important neurotransmitter that controls renal and cardiovascular organizations and regulates physiological activities. Abnormal concentrations of DA cause unfavorable neuronal illnesses such as Parkinson's disease, schizophrenia, and attention deficit hyperactivity disorder/attention deficit disorder. However, the DA concentration is exceedingly low in patients and difficult to detect with existing biosensors. In this study, we developed an organic field-effect-transistor-type (OFET) nonenzyme biosensor using platinum nanoparticle-decorated reduced graphene oxide (Pt_rGO) for ultrasensitive and selective DA detection. The Pt_rGOs were fabricated by reducing GO aqueous solution-containing Pt precursors (PtCl4) with a chemical reducing agent. The Pt_rGOs were immobilized on a graphene substrate by π-π interactions and a conducting-polymer source-drain electrode was patterned on the substrate to form the DA sensor. The resulting OFET sensor showed a high sensitivity to remarkably low DA concentrations (100 × 10-18 M) and selectivity among interfering molecules. Good stability was expected for the OFET sensor because it was fabricated without an enzymatic receptor, and π-π conjugation is a part of the immobilization process. Furthermore, the OFET sensors are flexible and offer the possibility of wide application as wearable and portable sensors.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Appl Mater Interfaces Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Appl Mater Interfaces Ano de publicação: 2017 Tipo de documento: Article