Determination of the R(-) and S(+)-enantiomers of vigabatrin in human plasma by ultra-high-performance liquid chromatography and tandem mass-spectrometry.
Duhamel, Paul; Ounissi, Marwa; Le Saux, Thomas; Bienayme, Hugues; Chiron, Catherine; Jullien, Vincent.
Afiliação
  • Duhamel P; Inserm U1129, Paris, France; Paris Descartes University, CEA, Gif-sur-Yvette, France.
  • Ounissi M; Inserm U1129, Paris, France; Paris Descartes University, CEA, Gif-sur-Yvette, France.
  • Le Saux T; PASTEUR, Département de Chimie, L'école normale supérieure, UPMC Univ Paris 06, CNRS, PSL Research University, Sorbonne Universités, 75005 Paris, France.
  • Bienayme H; Orphelia Pharma, Paris, France.
  • Chiron C; Inserm U1129, Paris, France; Paris Descartes University, CEA, Gif-sur-Yvette, France.
  • Jullien V; Inserm U1129, Paris, France; Paris Descartes University, CEA, Gif-sur-Yvette, France; Service de pharmacologie, Hôpital Européen Georges Pompidou, Paris, France. Electronic address: vincent.jullien@aphp.fr.
Article em En | MEDLINE | ID: mdl-29107733
ABSTRACT
An analytical method was developed for the quantification in plasma of the R and S enantiomers of vigabatrin (VGB), a drug used for the treatment of some refractory pediatric epileptic syndromes. After adding 50µL of the internal standard, which consisted of a 15mg/L solution of deuterated racemic VGB, and 100µL of water to 100µL of plasma samples, a protein precipitation was performed by adding 600µL of methanol. The supernatant was evaporated to dryness under a stream of nitrogen and the dry residue was reconstituted with 500µL of water. Then, 100µL of 0.01M o-phthaldialdehyde and 0.01M N-acetyl-l-cysteine in borate buffer (0.1M, pH=9.5) were added for pre-column derivatization of the enantiomers as diastereomeric isoindoles. One microliter of the resulting mixture was injected in the chromatographic system. The chromatographic separation was performed in gradient elution mode at a flow rate of 400µL/min using a phenomenex EVO C-18 column with a mobile phase composed of 5mM ammonium acetate and a methanolacetonitrile (6337v/v) mixture. Detection was performed by mass spectrometry in selected reaction monitoring mode using heated electrospray ionization in positive mode as the ion source. Intra- and inter-day precision and accuracy were lower than 15% over the calibration range (0.2-50mg/L for each enantiomer) and the method was successfully used to assess plasma concentrations of VGB in epileptic children.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Vigabatrina / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Child, preschool / Humans / Infant Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Vigabatrina / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Child, preschool / Humans / Infant Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Ano de publicação: 2017 Tipo de documento: Article