Your browser doesn't support javascript.
loading
Development and validation of a liquid chromatography-tandem mass spectrometry analytical method for the therapeutic drug monitoring of eight novel anticancer drugs.
Herbrink, M; de Vries, N; Rosing, H; Huitema, A D R; Nuijen, B; Schellens, J H M; Beijnen, J H.
Afiliação
  • Herbrink M; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
  • de Vries N; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
  • Rosing H; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
  • Huitema ADR; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
  • Nuijen B; Department of Clinical Pharmacy, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Schellens JHM; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
  • Beijnen JH; Department of Pharmacy and Pharmacology, The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital and MC Slotervaart, Amsterdam, The Netherlands.
Biomed Chromatogr ; 32(4)2018 Apr.
Article em En | MEDLINE | ID: mdl-29165815
To support therapeutic drug monitoring of patients with cancer, a fast and accurate method for simultaneous quantification of the registered anticancer drugs afatinib, axitinib, ceritinib, crizotinib, dabrafenib, enzalutamide, regorafenib and trametinib in human plasma using liquid chromatography tandem mass spectrometry was developed and validated. Human plasma samples were collected from treated patients and stored at -20°C. Analytes and internal standards (stable isotopically labeled analytes) were extracted with acetonitrile. An equal amount of 10 mm NH4 CO3 was added to the supernatant to yield the final extract. A 2 µL aliquot of this extract was injected onto a C18 -column, gradient elution was applied and triple-quadrupole mass spectrometry in positive-ion mode was used for detection. All results were within the acceptance criteria of the latest US Food and Drug Administration guidance and European Medicines Agency guidelines on method validation, except for the carry-over of ceritinib and crizotinib. These were corrected for by the injection order of samples. Additional stability tests were carried out for axitinib and dabrafenib in relation to their reported photostability. In conclusion, the described method to simultaneously quantify the eight selected anticancer drugs in human plasma was successfully validated and applied for therapeutic drug monitoring in cancer patients treated with these drugs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Monitoramento de Medicamentos / Espectrometria de Massas em Tandem / Antineoplásicos Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida / Monitoramento de Medicamentos / Espectrometria de Massas em Tandem / Antineoplásicos Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article