Your browser doesn't support javascript.
loading
Vector Flow Imaging Compared with Pulse Wave Doppler for Estimation of Peak Velocity in the Portal Vein.
Brandt, Andreas Hjelm; Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Bechsgaard, Thor; Lönn, Lars; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann.
Afiliação
  • Brandt AH; Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark. Electronic address: andreas.hjelm.brandt@regionh.dk.
  • Moshavegh R; Center for Fast Ultrasound Imaging, Technical University of Denmark, Lyngby, Denmark.
  • Hansen KL; Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
  • Bechsgaard T; Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
  • Lönn L; Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
  • Jensen JA; Center for Fast Ultrasound Imaging, Technical University of Denmark, Lyngby, Denmark.
  • Nielsen MB; Department of Radiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Ultrasound Med Biol ; 44(3): 593-601, 2018 03.
Article em En | MEDLINE | ID: mdl-29223701
ABSTRACT
The study described here investigated whether angle-independent vector flow imaging (VFI) technique estimates peak velocities in the portal vein comparably to pulsed wave Doppler (PWD). Furthermore, intra- and inter-observer agreement was assessed in a substudy. VFI and PWD peak velocities were estimated with from intercostal and subcostal views for 32 healthy volunteers, and precision analyses were conducted. Blinded to estimates, three physicians rescanned 10 volunteers for intra- and inter-observer agreement analyses. The precision of VFI and PWD was 18% and 28% from an intercostal view and 23% and 77% from a subcostal view, respectively. Bias between VFI and PWD was 0.57 cm/s (p = 0.38) with an intercostal view and 9.89 cm/s (p <0.001) with a subcostal view. Intra- and inter-observer agreement was highest for VFI (inter-observer intra-class correlation coefficient VFI 0.80, PWD 0.3; intra-observer intra-class correlation coefficient VFI 0.90, PWD 0.69). Regardless of scan view, VFI was more precise than PWD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Porta / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veia Porta / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2018 Tipo de documento: Article