Your browser doesn't support javascript.
loading
Improving oncoplastic breast tumor bed localization for radiotherapy planning using image registration algorithms.
Wodzinski, Marek; Skalski, Andrzej; Ciepiela, Izabela; Kuszewski, Tomasz; Kedzierawski, Piotr; Gajda, Janusz.
Afiliação
  • Wodzinski M; AGH University of Science and Technology, Department of Measurement and Electronics, al. A.Mickiewicza 30, PL30059, Krakow, Poland. Author to whom any correspondence should be addressed.
Phys Med Biol ; 63(3): 035024, 2018 01 31.
Article em En | MEDLINE | ID: mdl-29293469
ABSTRACT
Knowledge about tumor bed localization and its shape analysis is a crucial factor for preventing irradiation of healthy tissues during supportive radiotherapy and as a result, cancer recurrence. The localization process is especially hard for tumors placed nearby soft tissues, which undergo complex, nonrigid deformations. Among them, breast cancer can be considered as the most representative example. A natural approach to improving tumor bed localization is the use of image registration algorithms. However, this involves two unusual aspects which are not common in typical medical image registration the real deformation field is discontinuous, and there is no direct correspondence between the cancer and its bed in the source and the target 3D images respectively. The tumor no longer exists during radiotherapy planning. Therefore, a traditional evaluation approach based on known, smooth deformations and target registration error are not directly applicable. In this work, we propose alternative artificial deformations which model the tumor bed creation process. We perform a comprehensive evaluation of the most commonly used deformable registration algorithms B-Splines free form deformations (B-Splines FFD), different variants of the Demons and TV-L1 optical flow. The evaluation procedure includes quantitative assessment of the dedicated artificial deformations, target registration error calculation, 3D contour propagation and medical experts visual judgment. The results demonstrate that the currently, practically applied image registration (rigid registration and B-Splines FFD) are not able to correctly reconstruct discontinuous deformation fields. We show that the symmetric Demons provide the most accurate soft tissues alignment in terms of the ability to reconstruct the deformation field, target registration error and relative tumor volume change, while B-Splines FFD and TV-L1 optical flow are not an appropriate choice for the breast tumor bed localization problem, even though the visual alignment seems to be better than for the Demons algorithm. However, no algorithm could recover the deformation field with sufficient accuracy in terms of vector length and rotation angle differences.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X Tipo de estudo: Prognostic_studies Limite: Female / Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador / Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X Tipo de estudo: Prognostic_studies Limite: Female / Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article